Literature DB >> 27780765

Influence of strain on the corrosion of magnesium alloys and zinc in physiological environments.

Karin Törne1, Andreas Örnberg2, Jonas Weissenrieder3.   

Abstract

During implantation load-bearing devices experience stress that may influence its mechanical and corrosion profile and potentially lead to premature rupture. The susceptibility to stress corrosion cracking (SCC) of the Mg-Al alloy AZ61 and Zn was studied in simulated body fluid (m-SBF) and whole blood by slow strain rate (SSR) testing in combination with electrochemical impedance spectroscopy (EIS) and further ex situ analysis including scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy. AZ61 was found to be highly susceptible to SCC. EIS analysis show that although the majority of cracking occurred during the apparent plastic straining, cracking initiation occurs already in the elastic region at ∼50% of the ultimate tensile strength (UTS). Shifts in EIS phase angle and open circuit potential can be used to detect the onset of SCC. Zinc demonstrated a highly ductile behavior with limited susceptibility to SCC. No significant decrease in UTS was observed in m-SBF but a decrease in time to failure by ∼25% compared to reference samples indicates some effect on the mechanical properties during the ductile straining. The formation of micro cracks, ∼10μm deep, was indicated by the EIS analysis and later confirmed by ex situ SEM. The results of SSR analysis of zinc in whole blood showed a reduced effect compared to m-SBF and no cracks were detected. It appears that formation of an organic surface layer protects the corroding surface from cracking. These results highlight the importance of considering the effect of biological species on the degradation of implants in the clinical situation. STATEMENT OF SIGNIFICANCE: Strain may deteriorate the corrosion properties of metallic implants drastically. We study the influence of load on the corrosion properties of a magnesium alloy and zinc by a combination of electrochemical impedance spectroscopy (EIS) and slow strain rate analysis. This combination of techniques has previously not been used for studying degradation in physiological relevant electrolytes. EIS provide valuable information on the initial formation of cracks, detecting crack nucleation before feasible in slow strain rate analysis. This sensitivity of EIS shows the potential for electrochemical methods to be used for in situ monitoring crack formation of implants in more applied studies.
Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  AZ61; Biodegradable; Electrochemical impedance spectroscopy (EIS); Magnesium alloy; Slow strain rate (SSR); Stress corrosion cracking (SCC); Zinc

Mesh:

Substances:

Year:  2016        PMID: 27780765     DOI: 10.1016/j.actbio.2016.10.030

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  7 in total

1.  Influence of bovine serum albumin on corrosion behaviour of pure Zn in phosphate buffered saline.

Authors:  Lijun Liu; Lili Lu; Hai-Jun Zhang; Lu-Ning Wang
Journal:  J Mater Sci Mater Med       Date:  2021-08-18       Impact factor: 3.896

Review 2.  In silico modelling of the corrosion of biodegradable magnesium-based biomaterials: modelling approaches, validation and future perspectives.

Authors:  Aditya Joshi; George Dias; Mark P Staiger
Journal:  Biomater Transl       Date:  2021-09-28

3.  The Flow-Induced Degradation and Vascular Cellular Response Study of Magnesium-Based Materials.

Authors:  Tengda Shang; Kebing Wang; Shusheng Tang; Yang Shen; Lei Zhou; Lu Zhang; Yuancong Zhao; Xin Li; Lin Cai; Jin Wang
Journal:  Front Bioeng Biotechnol       Date:  2022-07-07

4.  Compressive Properties and Degradable Behavior of Biodegradable Porous Zinc Fabricated with the Protein Foaming Method.

Authors:  Qiqi Ge; Xiaoqian Liu; Aike Qiao; Yongliang Mu
Journal:  J Funct Biomater       Date:  2022-09-13

Review 5.  Recent Advances in Manufacturing Innovative Stents.

Authors:  Natalia Beshchasna; Muhammad Saqib; Honorata Kraskiewicz; Łukasz Wasyluk; Oleg Kuzmin; Oana Cristina Duta; Denisa Ficai; Zeno Ghizdavet; Alexandru Marin; Anton Ficai; Zhilei Sun; Vladimir F Pichugin; Joerg Opitz; Ecaterina Andronescu
Journal:  Pharmaceutics       Date:  2020-04-13       Impact factor: 6.321

6.  The effect of tensile and fluid shear stress on the in vitro degradation of magnesium alloy for stent applications.

Authors:  Xue-Nan Gu; Yun Lu; Fan Wang; Wenting Lin; Ping Li; Yubo Fan
Journal:  Bioact Mater       Date:  2018-09-01

Review 7.  Three-dimensional printing of metals for biomedical applications.

Authors:  J Ni; H Ling; S Zhang; Z Wang; Z Peng; C Benyshek; R Zan; A K Miri; Z Li; X Zhang; J Lee; K-J Lee; H-J Kim; P Tebon; T Hoffman; M R Dokmeci; N Ashammakhi; X Li; A Khademhosseini
Journal:  Mater Today Bio       Date:  2019-08-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.