Evaluation of a new microbeads assay for granulocyte antibody detection.

Undine Schulz1, Angelika Reil2, Volker Kiefel3, Jürgen Bux4, Rainer Moog1.   

Abstract

BACKGROUND: To reduce the risk of transfusion-associated acute lung injury (TRALI), a high number of plasma donors were tested for human leukocyte antigen (HLA) and human neutrophil antigen (HNA) antibodies. For HNA antibody detection, the gold standard is a combination of the granulocyte immunofluorescence test (GIFT) and the granulocyte agglutination test (GAT). However, these tests are not suitable for a high-throughput of samples. STUDY DESIGN AND METHODS: To evaluate the new generation of the LABScreen MULTI assay (One Lambda, Inc.), which has special new beads for all the known HNA specificities, including HNA-3a, 97 sera samples containing well-defined HNA antibodies were used. For background testing, we used 91 samples from plasma donors previously identified by GAT, GIFT, and the monoclonal antibody-specific immobilization of granulocyte antigens (MAIGA) assay.
RESULTS: Compared with previous tests, the new LABScreen MULTI assay was highly specific for the HNA-1a, HNA-1b, HNA-2, and HNA-3a antibody specificities required to prevent TRALI. Ninety-eight percent of the HNA-1a, HNA-1b, and HNA-2 antibodies could be detected as true positive; and 90% of the HNA-3a antibodies were recognized correctly as positive. False-positive reactions were identified in 5.5% of samples that previously tested negative.
CONCLUSION: The detection of HNA-3a antibody specificities could be integrated into the new LABScreen MULTI assay; however, we detected only 90%. In addition, we detected further HNA antibodies, such as HNA-1c, HNA-1d, and some HNA-3b and HNA-4a antibodies. The new generation of LABScreen MULTI is a great step toward feasible high-throughput testing for HNA antibodies. Nevertheless, GIFT and GAT remain the gold-standard methods for the differentiation of rare and currently unknown HNA specificities.
© 2016 AABB.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27774621     DOI: 10.1111/trf.13878

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Antibodies against human neutrophil antigens in non-transfused women with red blood cell alloimmunisation induced by pregnancy.

Authors:  Juliana Oliveira Martins; Elyse Moritz; Samira A Abbas; Larissa B Lopes; Melca M O Barros; Akemi K Chiba; Dante M Langhi; José O Bordin
Journal:  Blood Transfus       Date:  2020-10-14       Impact factor: 3.443

2.  Phagocytosis of Mature Granulocytes by Bone Marrow Macrophages in an Elderly Man with Adult-Onset Primary Autoimmune Neutropenia.

Authors:  Mitsutaka Nishimoto; Takahiko Nakane; Hideo Koh; Yasuhiro Nakashima; Ryosuke Yamamura; Hirohisa Nakamae; Masayuki Hino; Kensuke Ohta
Journal:  Hematol Rep       Date:  2022-05-25

3.  Leukocyte-Reactive Antibodies in Female Blood Donors: The Austrian Experience.

Authors:  Marlies Schönbacher; Nicole Aichinger; Lisa Weidner; Christof Jungbauer; Christoph Grabmer; Beate Schuha; Eva Rohde; Wolfgang Mayr; Günther Körmöczi
Journal:  Transfus Med Hemother       Date:  2020-09-23       Impact factor: 3.747