Literature DB >> 27770911

Rapid, efficient and selective preconcentration of benzo[a]pyrene (BaP) by molecularly imprinted composite cartridge and HPLC.

Mehmet Emin Çorman1, Canan Armutcu2, Lokman Uzun3, Adil Denizli2.   

Abstract

In this study, cryogel-based molecularly imprinted composite cartridges were designed for the rapid, efficient, and selective preconcentration of benzo[a]pyrene (BaP) from water samples. First, a BaP-imprinted poly(2-hydroxyethyl methacrylate-N-methacryloyl-(L)-phenylalanine) composite cartridge was synthesized under semi-frozen conditions and characterized by scanning electron microscopy, elemental analysis, Fourier transform infrared spectroscopy, and swelling tests. After the optimization of preconcentration parameters, i.e., pH and initial BaP concentration, the selectivity and preconcentration efficiency, and reusability of these cartridges were also evaluated. In selectivity experiments, BaP imprinted composite cartridge exhibited binding capacities 3.09, 9.52, 8.87, and 8.77-fold higher than that of the non-imprinted composite cartridge in the presence of competitors, such as benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), indeno[1,2,3-cd]pyrene (IcdP), and 1-naphthol, respectively. The method detection limit (MDL), relative standard deviation (RSD) and preconcentration efficiency (PE) of the synthesized composite cartridge were calculated as 24.86μg/L, 1.60%, and 349.6%, respectively.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Benzo[a]pyrene; Composite cartridge hydrophobic cryogel; Molecular imprinting; Polycyclic aromatic hydrocarbons; Preconcentration

Mesh:

Substances:

Year:  2016        PMID: 27770911     DOI: 10.1016/j.msec.2016.08.040

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  4 in total

1.  Endosulfan Elimination Using Amine-Modified Magnetic Diatomite as an Adsorbent.

Authors:  İhsan Alacabey
Journal:  Front Chem       Date:  2022-05-26       Impact factor: 5.545

2.  Simultaneous Determination of Aflatoxins and Benzo(a)pyrene in Vegetable Oils Using Humic Acid-Bonded Silica SPE HPLC-PHRED-FLD.

Authors:  Di Yuan; Liangxiao Zhang; Fei Ma; Peiwu Li
Journal:  Toxins (Basel)       Date:  2022-05-18       Impact factor: 5.075

3.  Nanoporous Gold Films Prepared by a Combination of Sputtering and Dealloying for Trace Detection of Benzo[a]pyrene Based on Surface Plasmon Resonance Spectroscopy.

Authors:  Li Wang; Xiu-Mei Wan; Ran Gao; Dan-Feng Lu; Zhi-Mei Qi
Journal:  Sensors (Basel)       Date:  2017-06-01       Impact factor: 3.576

Review 4.  Capacitive Biosensors and Molecularly Imprinted Electrodes.

Authors:  Gizem Ertürk; Bo Mattiasson
Journal:  Sensors (Basel)       Date:  2017-02-17       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.