Literature DB >> 27770685

Immobilized aptamer paper spray ionization source for ion mobility spectrometry.

Tahereh Zargar1, Taghi Khayamian2, Mohammad T Jafari1.   

Abstract

A selective thin-film microextraction based on aptamer immobilized on cellulose paper was used as a paper spray ionization source for ion mobility spectrometry (PSI-IMS), for the first time. In this method, the paper is not only used as an ionization source but also it is utilized for the selective extraction of analyte, based on immobilized aptamer. This combination integrates both sample preparation and analyte ionization in a Whatman paper. To that end, an appropriate sample introduction system with a novel design was constructed for the paper spray ionization source. Using this system, a continuous solvent flow works as an elution and spray solvent simultaneously. In this method, analyte is adsorbed on a triangular paper with immobilized aptamer and then it is desorbed and ionized by elution solvent and applied high voltage on paper, respectively. The effects of different experimental parameters such as applied voltage, angle of paper tip, distance between paper tip and counter electrode, elution solvent type, and solvent flow rate were optimized. The proposed method was exhaustively validated in terms of sensitivity and reproducibility by analyzing the standard solutions of codeine and acetamiprid. The analytical results obtained are promising enough to ensure the use of immobilized aptamer paper-spray as both the extraction and ionization techniques in IMS for direct analysis of biomedicine.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Ion mobility spectrometry; Paper spray ionization

Mesh:

Substances:

Year:  2016        PMID: 27770685     DOI: 10.1016/j.jpba.2016.10.014

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

1.  Molecularly imprinted graphite spray ionization-ion mobility spectrometry: application to trace analysis of the pesticide propoxur.

Authors:  Tahereh Zargar; Mohammad T Jafari; Taghi Khayamian
Journal:  Mikrochim Acta       Date:  2019-06-03       Impact factor: 5.833

2.  Aptamer-modified carbon nanomaterial based sorption coupled to paper spray ion mobility spectrometry for highly sensitive and selective determination of methamphetamine.

Authors:  Tahereh Zargar; Taghi Khayamian; Mohammad T Jafari
Journal:  Mikrochim Acta       Date:  2018-01-10       Impact factor: 5.833

Review 3.  Paper spray ionization mass spectrometry: recent advances and clinical applications.

Authors:  Spencer Chiang; Wenpeng Zhang; Zheng Ouyang
Journal:  Expert Rev Proteomics       Date:  2018-09-26       Impact factor: 3.940

4.  Solvent-Assisted Paper Spray Ionization Mass Spectrometry (SAPSI-MS) for the Analysis of Biomolecules and Biofluids.

Authors:  Nicoló Riboni; Alessandro Quaranta; Hitesh V Motwani; Nicklas Österlund; Astrid Gräslund; Federica Bianchi; Leopold L Ilag
Journal:  Sci Rep       Date:  2019-07-16       Impact factor: 4.379

Review 5.  Monoclonal Antibodies Application in Lateral Flow Immunochromatographic Assays for Drugs of Abuse Detection.

Authors:  Zidane Qriouet; Yahia Cherrah; Hassan Sefrioui; Zineb Qmichou
Journal:  Molecules       Date:  2021-02-18       Impact factor: 4.411

Review 6.  Pesticide Aptasensors-State of the Art and Perspectives.

Authors:  Kamonrat Phopin; Tanawut Tantimongcolwat
Journal:  Sensors (Basel)       Date:  2020-11-28       Impact factor: 3.576

  6 in total