Literature DB >> 27769436

Sensitive and selective turn off-on fluorescence detection of heparin based on the energy transfer platform using the BSA-stabilized Au nanoclusters/amino-functionalized graphene oxide hybrids.

Jing Lan1, Hong Yan Zou1, Qiang Wang1, Ping Zeng1, Yuan Fang Li2, Cheng Zhi Huang3.   

Abstract

An ultra-sensitive and selective turn off-on fluorescence detection of heparin based on the energy transfer in the BSA-stabilized gold nanoclusters/amino-functionalized graphene oxide (BSA-AuNCs/NH2-GO) hybrids was successfully realized. The BSA-AuNCs containing amounts of carboxyl groups could be absorbed on the surface of NH2-GO through the electrostatic interaction, which resulted in the fluorescence quenching of BSA-AuNCs with high efficiency. However, heparin, possessing high density of negative charge, could compete with BSA-AuNCs to bind NH2-GO and block the energy transfer from BSA-AuNCs to NH2-GO. The fluorescence recovery of BSA-AuNCs was closely related to the amount of heparin and there was a good linear relationship between fluorescence recovery of BSA-AuNCs and heparin over the range of 100ng/mL to 30μg/mL with a detection limit of 40ng/mL. What's more, the fluorescence assay was successfully applied for heparin sensing in human serums and intracellular imaging.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amino-functionalized graphene oxide; BSA-stabilized gold nanoclusters; Energy transfer; Heparin; Intracellular imaging

Mesh:

Substances:

Year:  2016        PMID: 27769436     DOI: 10.1016/j.talanta.2016.08.081

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A fluorometric clenbuterol immunoassay based on the use of organic/inorganic hybrid nanoflowers modified with gold nanoclusters and artificial antigen.

Authors:  Tao Peng; Jianyi Wang; Sijun Zhao; Sanlei Xie; Kai Yao; Pimiao Zheng; Sihan Wang; Yuebin Ke; Haiyang Jiang
Journal:  Mikrochim Acta       Date:  2018-07-07       Impact factor: 5.833

2.  A signal-on ratiometric fluorometric heparin assay based on the direct interaction between amino-modified carbon dots and DNA.

Authors:  Jianyong Huang; Fenglan Li; Rubin Guo; Yuyuan Chen; Zhenzhen Wang; Chengfei Zhao; Yanjie Zheng; Shaohuang Weng; Xinhua Lin
Journal:  Mikrochim Acta       Date:  2018-04-21       Impact factor: 5.833

3.  Colorimetric and fluorometric aggregation-based heparin assay by using gold nanoclusters and gold nanoparticles.

Authors:  Zhipeng Zhang; Sha Li; Pengcheng Huang; Jiayu Feng; Fang-Ying Wu
Journal:  Mikrochim Acta       Date:  2019-11-16       Impact factor: 5.833

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.