Preparation of a new polymeric ionic liquid-based sorbent for stir cake sorptive extraction of trace antimony in environmental water samples.

Yong Zhang1, Meng Mei1, Tong Ouyang1, Xiaojia Huang2.   

Abstract

In this work, a new polymeric ionic liquid (PIL)-based sorbent was prepared by in-situ polymerization of 3-(1-ethyl imidazolium-3-yl) propyl-methacrylamido bromide and ethylene dimethacrylate and was used as medium for stir cake sorptive extraction (SCSE) of trace antimony in environmental water samples. The sorbent EPBED was characterized with infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. A method for determination of trace antimony in water samples was developed based on the combination of SCSE/EPBED and hydride generation atomic fluorescence spectrometry (HG-AFS). Under the optimal extraction conditions, the linear dynamic range of developed method was found to be 0.20-100.0μg/L with good coefficients of correlation (R2=0.9904) and LOD value as low as 0.084μg/L. The method showed good reproducibility of results in terms of intra- and inter-day precisions with corresponding relative standard deviations (RSDs) of less than 9%. Recoveries obtained for the determination of antimony in spiked samples ranged from 80.4% to 107% with RSDs below 10% in all cases.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antimony; Atomic fluorescence spectrometry; Polymeric ionic liquid; Stir cake sorptive extraction; Water

Year:  2016        PMID: 27769420     DOI: 10.1016/j.talanta.2016.08.063

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Determination of Trace Antimony (III) in Water Samples with Single Drop Microextraction Using BPHA-[C4mim][PF6] System Followed by Graphite Furnace Atomic Absorption Spectrometry.

Authors:  Xiaoshan Huang; Mingxin Guan; Zhuliangzi Lu; Yiping Hang
Journal:  Int J Anal Chem       Date:  2018-08-01       Impact factor: 1.885

2.  Magnetic Ion Imprinted Polymers (MIIPs) for Selective Extraction and Preconcentration of Sb(III) from Environmental Matrices.

Authors:  Silindokuhle Jakavula; Nkositetile Raphael Biata; Kgogobi M Dimpe; Vusumzi Emmanuel Pakade; Philiswa Nosizo Nomngongo
Journal:  Polymers (Basel)       Date:  2021-12-22       Impact factor: 4.329

Review 3.  Recent Advances in Applications of Ionic Liquids in Miniaturized Microextraction Techniques.

Authors:  Maria Kissoudi; Victoria Samanidou
Journal:  Molecules       Date:  2018-06-13       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.