Literature DB >> 27768366

Anisotropic X-Ray Dark-Field Tomography: A Continuous Model and its Discretization.

M Wieczorek1, F Schaff2, F Pfeiffer2,3, T Lasser1.   

Abstract

The x-ray dark-field signal measured in grating interferometers is anisotropic, depending on both the beam direction and the grating orientation with respect to the sample. We present a novel general closed-form, continuous forward model of the anisotropic dark-field signal. Furthermore, we derive a discretization using spherical harmonics, leading to a large-scale linear inverse problem. We present first experimental results of a wooden sample, demonstrating marked advantages over previous results, in particular, the resolution of multiple scattering directions in one volume element.

Year:  2016        PMID: 27768366     DOI: 10.1103/PhysRevLett.117.158101

Source DB:  PubMed          Journal:  Phys Rev Lett        ISSN: 0031-9007            Impact factor:   9.161


  7 in total

1.  Tomography of dark-field scatter including single-exposure Moiré fringe analysis with X-ray biprism interferometry-A simulation study.

Authors:  Weijie Tao; Yongjin Sung; Sally Ji Who Kim; Qiu Huang; Grant T Gullberg; Youngho Seo; Michael Fuller
Journal:  Med Phys       Date:  2021-08-18       Impact factor: 4.506

2.  Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT).

Authors:  Y Sharma; F Schaff; M Wieczorek; F Pfeiffer; T Lasser
Journal:  Sci Rep       Date:  2017-06-09       Impact factor: 4.379

3.  Validation study of small-angle X-ray scattering tensor tomography.

Authors:  Manuel Guizar-Sicairos; Marios Georgiadis; Marianne Liebi
Journal:  J Synchrotron Radiat       Date:  2020-04-22       Impact factor: 2.616

4.  Fast acquisition protocol for X-ray scattering tensor tomography.

Authors:  Jisoo Kim; Matias Kagias; Federica Marone; Zhitian Shi; Marco Stampanoni
Journal:  Sci Rep       Date:  2021-11-29       Impact factor: 4.379

5.  X-ray dark-field tomography reveals tooth cracks.

Authors:  Christoph Jud; Yash Sharma; Benedikt Günther; Jochen Weitz; Franz Pfeiffer; Daniela Pfeiffer
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

6.  Brain Connectivity Exposed by Anisotropic X-ray Dark-field Tomography.

Authors:  Matthias Wieczorek; Florian Schaff; Christoph Jud; Daniela Pfeiffer; Franz Pfeiffer; Tobias Lasser
Journal:  Sci Rep       Date:  2018-09-25       Impact factor: 4.379

7.  The versatile X-ray beamline of the Munich Compact Light Source: design, instrumentation and applications.

Authors:  Benedikt Günther; Regine Gradl; Christoph Jud; Elena Eggl; Juanjuan Huang; Stephanie Kulpe; Klaus Achterhold; Bernhard Gleich; Martin Dierolf; Franz Pfeiffer
Journal:  J Synchrotron Radiat       Date:  2020-07-31       Impact factor: 2.616

  7 in total