Literature DB >> 27767345

Bayer Filter Snapshot Hyperspectral Fundus Camera for Human Retinal Imaging.

Joel Kaluzny1, Hao Li2, Wenzhong Liu2, Peter Nesper1, Justin Park1, Hao F Zhang1,2, Amani A Fawzi2.   

Abstract

PURPOSE: To demonstrate the versatility and performance of a compact Bayer filter snapshot hyperspectral fundus camera for in-vivo clinical applications including retinal oximetry and macular pigment optical density measurements.
METHODS: 12 healthy volunteers were recruited under an Institutional Review Board (IRB) approved protocol. Fundus images were taken with a custom hyperspectral camera with a spectral range of 460-630 nm. We determined retinal vascular oxygen saturation (sO2) for the healthy population using the captured spectra by least squares curve fitting. Additionally, macular pigment optical density was localized and visualized using multispectral reflectometry from selected wavelengths.
RESULTS: We successfully determined the mean sO2 of arteries and veins of each subject (ages 21-80) with excellent intrasubject repeatability (1.4% standard deviation). The mean arterial sO2 for all subjects was 90.9% ± 2.5%, whereas the mean venous sO2 for all subjects was 64.5% ± 3.5%. The mean artery-vein (A-V) difference in sO2 varied between 20.5% and 31.9%. In addition, we were able to reveal and quantify macular pigment optical density.
CONCLUSIONS: We demonstrated a single imaging tool capable of oxygen saturation and macular pigment density measurements in vivo. The unique combination of broad spectral range, high spectral-spatial resolution, rapid and robust imaging capability, and compact design make this system a valuable tool for multifunction spectral imaging that can be easily performed in a clinic setting.

Entities:  

Keywords:  Hyperspectral fundus imaging; macular pigment; oximetry; spectroscopy

Mesh:

Substances:

Year:  2016        PMID: 27767345      PMCID: PMC5389919          DOI: 10.1080/02713683.2016.1221976

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  37 in total

Review 1.  Macular pigment and age related macular degeneration.

Authors:  S Beatty; M Boulton; D Henson; H H Koh; I J Murray
Journal:  Br J Ophthalmol       Date:  1999-07       Impact factor: 4.638

2.  In vivo measurement of the oxygen saturation of retinal vessels in healthy volunteers.

Authors:  D Schweitzer; M Hammer; J Kraft; E Thamm; E Königsdörffer; J Strobel
Journal:  IEEE Trans Biomed Eng       Date:  1999-12       Impact factor: 4.538

3.  Macular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry.

Authors:  F C Delori; D G Goger; B R Hammond; D M Snodderly; S A Burns
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-06       Impact factor: 2.129

Review 4.  A review of methods for human retinal oximetry.

Authors:  Alon Harris; Robert B Dinn; Larry Kagemann; Ehud Rechtman
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2003 Mar-Apr

5.  A study of retinal venous blood oxygen saturation in human subjects by photographic means.

Authors:  J B HICKAM; R FRAYSER; J C ROSS
Journal:  Circulation       Date:  1963-03       Impact factor: 29.690

6.  Hyperspectral imaging for measurement of oxygen saturation in the optic nerve head.

Authors:  Bahram Khoobehi; James M Beach; Hiroyuki Kawano
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-05       Impact factor: 4.799

Review 7.  Objective determination of the macular pigment optical density using fundus reflectance spectroscopy.

Authors:  Tos T J M Berendschot; Dirk van Norren
Journal:  Arch Biochem Biophys       Date:  2004-10-15       Impact factor: 4.013

8.  On the age dependency of the macular pigment optical density.

Authors:  Tos T J M Berendschot; Dirk van Norren
Journal:  Exp Eye Res       Date:  2005-07-15       Impact factor: 3.467

9.  A new method for the measurement of oxygen saturation at the human ocular fundus.

Authors:  D Schweitzer; E Thamm; M Hammer; J Kraft
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

Review 10.  Risk factors for age-related maculopathy are associated with a relative lack of macular pigment.

Authors:  John M Nolan; Jim Stack; Orla O' Donovan; Edward Loane; Stephen Beatty
Journal:  Exp Eye Res       Date:  2006-11-01       Impact factor: 3.467

View more
  4 in total

1.  Fiber pattern removal and image reconstruction method for snapshot mosaic hyperspectral endoscopic images.

Authors:  Pu Wang; Gianluca Turcatel; Cosimo Arnesano; David Warburton; Scott E Fraser; Francesco Cutrale
Journal:  Biomed Opt Express       Date:  2018-01-25       Impact factor: 3.732

2.  Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry.

Authors:  Karel Van Keer; Jan Van Keer; João Barbosa Breda; Vahid Nassiri; Cathy De Deyne; Cornelia Genbrugge; Luís Abegão Pinto; Ingeborg Stalmans; Evelien Vandewalle
Journal:  PLoS One       Date:  2018-01-05       Impact factor: 3.240

Review 3.  Advances in Retinal Oximetry.

Authors:  Anupam K Garg; Darren Knight; Leonardo Lando; Daniel L Chao
Journal:  Transl Vis Sci Technol       Date:  2021-02-05       Impact factor: 3.283

4.  Hyperspectral Imaging and the Retina: Worth the Wave?

Authors:  Sophie Lemmens; Jan Van Eijgen; Karel Van Keer; Julie Jacob; Sinéad Moylett; Lies De Groef; Toon Vancraenendonck; Patrick De Boever; Ingeborg Stalmans
Journal:  Transl Vis Sci Technol       Date:  2020-08-05       Impact factor: 3.283

  4 in total