Membrane-tube-type glaucoma shunt device for refractory glaucoma surgery.

Jong Chul Han1, Young Hoon Hwang2, Byung Heon Ahn3.   

Abstract

PURPOSE: To evaluate the safety and efficacy of a novel membrane-tube (MT)-type glaucoma shunt device for refractory glaucoma surgery. The device consists of an expanded polytetrafluoroethylene membranous reservoir, as well as a silicone tube (300-μm external and 200-μm internal diameter) with an intraluminal stent. We named the device "Finetube MT".
METHODS: The Finetube MT was implanted into 44 glaucomatous eyes that had insufficient intraocular pressure (IOP) control despite medical treatment or previous trabeculectomy. The membranous reservoir was placed underneath the Tenon's capsule, with each end located below the recti muscles; the tube was placed in the anterior chamber through a partial-thickness scleral track. We investigated the baseline and post-operative IOP values, the number of IOP-lowering medications used, and complications.
RESULTS: The mean age of the subjects was 51.6 ± 17.2 years, and the mean follow-up duration was 22.5 ± 12.0 months. One year after the surgery, the mean IOP had decreased from 32.8 ± 12.2 mmHg to 16.9 ± 6.4 mmHg (48.5 % reduction; p < 0.01), and the mean number of IOP-lowering medications used had decreased from 2.5 ± 0.8 to 1.1 ± 0.9 (p < 0.01). We considered the surgery as a success when the IOP was between 6 and 21 mmHg, and had been reduced by ≥ 20 % from baseline; by this standard, the success rate was 92.4 % after 1 year, and 85.0 % after 3 years. Neither postoperative ocular hypotony-related complications nor tube exposure occurred in any case.
CONCLUSIONS: The Finetube MT showed promising surgical outcomes as a treatment for refractory glaucoma, with minimal risk of postoperative ocular hypotony or tube-related complications.

Entities:  

Keywords:  Glaucoma; Glaucoma drainage device; Intraocular pressure; Surgery; Trabeculectomy

Mesh:

Year:  2016        PMID: 27766415     DOI: 10.1007/s00417-016-3510-z

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  10 in total

1.  A comparison of the clinical effect between e-PTFE membrane-tube implant and Ahmed glaucoma valve implant for the treatment of refractory glaucoma.

Authors:  You-Jin Choi; Chang-Sik Kim; Byung-Heon Ahn
Journal:  Korean J Ophthalmol       Date:  2003-12

2.  Clinical experience of e-PTFE membrane implant surgery for refractory glaucoma.

Authors:  C Kim; Y Kim; S Choi; S Lee; B Ahn
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

3.  Five-year treatment outcomes in the Ahmed Baerveldt comparison study.

Authors:  Donald L Budenz; Keith Barton; Steven J Gedde; William J Feuer; Joyce Schiffman; Vital P Costa; David G Godfrey; Yvonne M Buys
Journal:  Ophthalmology       Date:  2014-10-17       Impact factor: 12.079

Review 4.  Evidenced-based comparison of aqueous shunts.

Authors:  Steven J Gedde; Joseph F Panarelli; Michael R Banitt; Richard K Lee
Journal:  Curr Opin Ophthalmol       Date:  2013-03       Impact factor: 3.761

Review 5.  Complications of tube implants and their management.

Authors:  Andrew K Bailey; Steven R Sarkisian
Journal:  Curr Opin Ophthalmol       Date:  2014-03       Impact factor: 3.761

6.  Postoperative complications in the Tube Versus Trabeculectomy (TVT) study during five years of follow-up.

Authors:  Steven J Gedde; Leon W Herndon; James D Brandt; Donald L Budenz; William J Feuer; Joyce C Schiffman
Journal:  Am J Ophthalmol       Date:  2012-01-14       Impact factor: 5.258

7.  A membranous drainage implant in glaucoma filtering surgery: animal trial.

Authors:  H B Bae; C S Kim; B H Ahn
Journal:  Korean J Ophthalmol       Date:  1988-12

8.  The Ahmed versus Baerveldt study: three-year treatment outcomes.

Authors:  Panos G Christakis; James C Tsai; Jeffrey W Kalenak; David Zurakowski; Louis B Cantor; Jeffrey A Kammer; Iqbal I K Ahmed
Journal:  Ophthalmology       Date:  2013-06-21       Impact factor: 12.079

9.  Ahmed glaucoma valves in refractory glaucoma: a 7-year audit.

Authors:  Peter K Wishart; Anshoo Choudhary; David Wong
Journal:  Br J Ophthalmol       Date:  2009-12-03       Impact factor: 4.638

10.  Novel membrane-tube type glaucoma shunt device for glaucoma surgery.

Authors:  Byung Heon Ahn; Young Hoon Hwang; Jong Chul Han
Journal:  Clin Exp Ophthalmol       Date:  2016-06-07       Impact factor: 4.207

  10 in total
  4 in total

1.  Baerveldt® glaucoma implant surgery with the double scleral flap technique to prevent Hoffman elbow exposure.

Authors:  Naoki Tojo; Tomoko Ueda-Consolvo; Shuichiro Yanagisawa; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-07-22       Impact factor: 3.117

2.  Implantation of a Modified Baerveldt Glaucoma Implant with a Smaller Tube and Intraluminal Stent.

Authors:  Min Kyung Kim; Young Hoon Hwang; Byung Heon Ahn
Journal:  Korean J Ophthalmol       Date:  2017-02-02

3.  Surgical outcomes of membrane-tube-type glaucoma shunt device in indigenous West Africans.

Authors:  Olusola Olawoye; Tarela Sarimiye; Adeyinka Ashaye; Young Hoon Hwang; Jong Chul Han; Byung Heon Ahn
Journal:  Clin Ophthalmol       Date:  2018-02-02

4.  Fluid Dynamics of Small Diameter Tubes Used in Membrane-tube Type Glaucoma Shunt Devices.

Authors:  Jong Chul Han; Young Hoon Hwang; Byung Heon Ahn
Journal:  Korean J Ophthalmol       Date:  2019-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.