Literature DB >> 27763855

Hypersensitivity Reactions to Implanted Metal Devices: Facts and Fictions.

Z W Teo Wendy1, P C Schalock1.   

Abstract

The use of metals in the medical field has become increasingly prevalent over the past few decades. Patients find themselves being exposed to metals in a variety of ways, ranging from external exposure to instruments such as the stainless steel in surgical blades to internal exposure via medical devices being implanted in their bodies. There has been growing interest in the possibility of developing hypersensitivity reactions to constituent metals in medical implant devices, both in cutaneous and systemic forms. Hypersensitivity reactions to metals are uncommon, but they are reported and require appropriate evaluation and management, particularly if they are symptomatic. In view of the lack of consensus in the field on the appropriate steps to evaluate and manage patients with suspected metal hypersensitivity reactions, this review aims to analyze current evidence on hypersensitivity reactions to metallic implants in orthopedic surgery, endovascular surgery, obstetrics and gynecology, and dental surgery.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27763855     DOI: 10.18176/jiaci.0095

Source DB:  PubMed          Journal:  J Investig Allergol Clin Immunol        ISSN: 1018-9068            Impact factor:   4.333


  5 in total

1.  Cerebral vasculitis due to nickel hypersensitivity: a case of intracranial "device syndrome".

Authors:  A Digiovanni; L Gentile; M Caulo; M Onofrj; S L Sensi; M V De Angelis
Journal:  Neurol Sci       Date:  2022-05-18       Impact factor: 3.830

2.  Systemic contact dermatitis to a surgical implant presenting as red decorative tattoo reaction.

Authors:  Hana K Cobb; Michi M Shinohara; Jason T Huss; Marshall P Welch; Jennifer M Gardner
Journal:  JAAD Case Rep       Date:  2017-07-19

3.  Letter to the Editor: Metal hypersensitivity reactions in the context of Essure.

Authors:  Kory Markel; Bruce Brod; Sharon E Jacob
Journal:  Case Rep Womens Health       Date:  2018-10-30

Review 4.  Use of Nanotechnology to Mitigate Biofouling in Stainless Steel Devices Used in Food Processing, Healthcare, and Marine Environments.

Authors:  Hugo Pérez; Gregorio Vargas; Rodolfo Silva
Journal:  Toxics       Date:  2022-01-12

5.  The Effect of Neutrophil-Derived Products on the Function of Leukocytes Obtained after Titanium Implantation in the Ovine Model.

Authors:  Joanna Zdziennicka; Joanna Wessely-Szponder; Grzegorz Starobrat; Andrzej Junkuszew
Journal:  Animals (Basel)       Date:  2021-12-15       Impact factor: 2.752