Literature DB >> 27755056

A Comparison Between the Conventional and the Laryngoscope-Assisted Lightwand Intubation Techniques in Patients With Cervical Immobilization: A Prospective Randomized Study.

Eugene Kim1, Byung-Gun Kim, Young-Jin Lim, Young-Tae Jeon, Jung-Won Hwang, Seo-Yun Lee, Hee-Pyoung Park.   

Abstract

BACKGROUND: Positioning of a lightwand in the midline of the oral cavity can be challenging in patients with cervical immobilization. Direct laryngoscopy may permit the lightwand tip to more easily access the glottic opening. We tested our hypothesis that a laryngoscope-assisted lightwand technique allows more successful endotracheal intubation than does a conventional lightwand approach.
METHODS: A total of 162 patients requiring cervical immobilization during intubation for cervical spine surgery were allocated randomly to 2 groups. The conventional lightwand technique (group C, n = 80) or the laryngoscope-assisted lightwand technique (group L, n = 82) was used for endotracheal intubation. In the group L, a Macintosh laryngoscope was inserted into the oral cavity, advanced until the epiglottis tip was visible, but not used to lift the epiglottis tip. The lightwand tip was placed below the epiglottis under direct view of the epiglottis tip. The primary outcome (the initial intubation success rate) and secondary outcomes (intubation time, hemodynamic changes, and postoperative airway complications) were evaluated.
RESULTS: The initial intubation success rate was significantly lower (75% vs 89%; relative risk [95% confidence interval]: 1.2 [1.0-1.4]; P = .034) in group C than group L. The intubation time (22 ± 13 vs 24 ± 12 seconds; mean difference [98.33% confidence interval]: 2.4 [-2.3 to 7.2]; P = .217) did not differ between groups. Postoperative sore throat score, incidences of hypertension and tachycardia, postoperative oral mucosal bleeding, and hoarseness also did not differ between groups.
CONCLUSIONS: Laryngoscope-assisted lightwand intubation did not increase intubation time, and it increased first attempt intubation rates compared with traditional lightwand intubation in patients requiring cervical immobilization for cervical spine surgery.

Entities:  

Mesh:

Year:  2017        PMID: 27755056     DOI: 10.1213/ANE.0000000000001661

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  1 in total

1.  Comparison between use of single lightwand and video laryngoscope-guided lightwand for tracheal intubation in simulated cervical spine-immobilized patients: a single-blind randomized study.

Authors:  Ha Yeon Kim; Eun Jung Kim; Hei Jin Yoon; Byungwoong Ko; Seung Yeon Choi; Bon-Nyeo Koo
Journal:  J Int Med Res       Date:  2019-09-25       Impact factor: 1.671

  1 in total