Literature DB >> 27754563

Thermal comfort, perceived air quality, and cognitive performance when personally controlled air movement is used by tropically acclimatized persons.

S Schiavon1, B Yang2,3,4, Y Donner5, V W-C Chang3, W W Nazaroff6.   

Abstract

In a warm and humid climate, increasing the temperature set point offers considerable energy benefits with low first costs. Elevated air movement generated by a personally controlled fan can compensate for the negative effects caused by an increased temperature set point. Fifty-six tropically acclimatized persons in common Singaporean office attire (0.7 clo) were exposed for 90 minutes to each of five conditions: 23, 26, and 29°C and in the latter two cases with and without occupant-controlled air movement. Relative humidity was maintained at 60%. We tested thermal comfort, perceived air quality, sick building syndrome symptoms, and cognitive performance. We found that thermal comfort, perceived air quality, and sick building syndrome symptoms are equal or better at 26°C and 29°C than at the common set point of 23°C if a personally controlled fan is available for use. The best cognitive performance (as indicated by task speed) was obtained at 26°C; at 29°C, the availability of an occupant-controlled fan partially mitigated the negative effect of the elevated temperature. The typical Singaporean indoor air temperature set point of 23°C yielded the lowest cognitive performance. An elevated set point in air-conditioned buildings augmented with personally controlled fans might yield benefits for reduced energy use and improved indoor environmental quality in tropical climates.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  air movement; cognitive performance; perceived air quality; sick building syndrome; thermal comfort; tropically acclimatized person

Mesh:

Year:  2016        PMID: 27754563     DOI: 10.1111/ina.12352

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  3 in total

1.  Building and indoor environmental quality assessment of Nigerian primary schools: A pilot study.

Authors:  Oluyemi Toyinbo; Wanda Phipatanakul; Richard Shaughnessy; Ulla Haverinen-Shaughnessy
Journal:  Indoor Air       Date:  2019-03-20       Impact factor: 5.770

2.  Quantifying the impact of heat on human physical work capacity; part II: the observed interaction of air velocity with temperature, humidity, sweat rate, and clothing is not captured by most heat stress indices.

Authors:  Josh Foster; James W Smallcombe; Simon Hodder; Ollie Jay; Andreas D Flouris; George Havenith
Journal:  Int J Biometeorol       Date:  2021-11-06       Impact factor: 3.787

3.  Effects of thermal sensation and acclimatization on cognitive performance of adult female students in Saudi Arabia using multivariable-multilevel statistical modeling.

Authors:  Riham Ahmed; Marcella Ucci; Dejan Mumovic; Emmanouil Bagkeris
Journal:  Indoor Air       Date:  2022-02       Impact factor: 6.554

  3 in total