Impact of permanent pacemaker on mortality after transcatheter aortic valve implantation: the PRAGMATIC (Pooled Rotterdam-Milan-Toulouse in Collaboration) Pacemaker substudy.

Gennaro Giustino1, Robert M A Van der Boon, Javier Molina-Martin de Nicolas, Nicolas Dumonteil, Alaide Chieffo, Peter P T de Jaegere, Didier Tchetche, Bertrand Marcheix, Damien Millischer, Romain Cassagneau, Didier Carrié, Nicolas M Van Mieghem, Antonio Colombo.   

Abstract

AIMS: We sought to evaluate the impact of permanent pacemaker (PPM) implantation on two-year mortality and one-year left ventricular ejection fraction recovery (∆LVEFR=one-year LVEF-baseline LVEF) after transcatheter aortic valve implantation (TAVI). METHODS AND
RESULTS: We pooled patient-level data from four European institutions with significant TAVI volume. Outcomes were compared between patients without PPM (no-PPM), patients with PPM prior to TAVI (old-PPM) and patients with PPM implanted after TAVI (new-PPM). Out of 1,062 patients included in the pooled data set, 783 (73.7%) were in the no-PPM group, 164 (15.4%) in the new-PPM group and 115 (10.8%) in the old-PPM group. All-cause and cardiovascular mortality at two years were similar for patients with no-PPM and new-PPM (adjusted HR 1.11, 95% CI: 0.74-1.67; p=0.62; and adjusted HR 1.16, 95% CI: 0.68-1.98; p=0.59). Conversely, old-PPM was associated with increased risk of both all-cause and cardiovascular mortality vs. no-PPM. By multivariable analysis new-PPM did not affect LVEFR, while old-PPM did. We observed a multiplicative interaction, between new-PPM and post-procedural aortic regurgitation ≥1+ on two-year mortality and one-year LVEFR, with increased risk of death and impaired LVEFR in patients with new-PPM and post-procedural aortic regurgitation (PPAR) ≥1+ (both pinteraction<0.0001).
CONCLUSIONS: In patients undergoing TAVI, the presence of a PPM at baseline yielded a negative effect on long-term prognosis while new-PPM did not. The combination of new-PPM with PPAR adversely impacts on survival and LV function recovery.

Entities:  

Mesh:

Year:  2016        PMID: 27753605     DOI: 10.4244/EIJV12I9A192

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  9 in total

1.  Mid- to Long-Term Clinical and Echocardiographic Effects of Post-procedural Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Shun Xu; Enrui Zhang; Zhiyong Qian; Jinyu Sun; Fengwei Zou; Yao Wang; Xiaofeng Hou; Jiangang Zou
Journal:  Front Cardiovasc Med       Date:  2022-06-28

2.  Impact of postprocedural permanent pacemaker implantation on clinical outcomes after transcatheter aortic valve replacement: a systematic review and meta-analysis.

Authors:  Ziwei Xi; Tong Liu; Jing Liang; Yu-Jie Zhou; Wei Liu
Journal:  J Thorac Dis       Date:  2019-12       Impact factor: 2.895

Review 3.  Spotlight on the SAPIEN 3 transcatheter heart valve.

Authors:  Tobias Rheude; Johannes Blumenstein; Helge Möllmann; Oliver Husser
Journal:  Med Devices (Auckl)       Date:  2018-10-01

Review 4.  Rate and Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Current Status.

Authors:  Eleonora Russo; Domenico R Potenza; Michela Casella; Raimondo Massaro; Giulio Russo; Maurizio Braccio; Antonio Dello Russo; Mauro Cassese
Journal:  Curr Cardiol Rev       Date:  2019

5.  Utility of conventional aortic root shot angiography for SAPIEN 3 prosthesis sizing in TAVI: feasibility and inter-reader variability.

Authors:  Laura Gansera; Bernhard Ulm; Peter Bramlage; Stephan Krapf; Frank Oertel; Tobias Mueller-Honold; Wolfgang von Scheidt; Christian Thilo
Journal:  Open Heart       Date:  2019-12-29

6.  Impact of Cusp-Overlap View for TAVR with Self-Expandable Valves on 30-Day Conduction Disturbances.

Authors:  Oscar A Mendiz; Marko Noč; Carlos M Fava; Luis Abel Gutiérrez Jaikel; Matias Sztejfman; Aleš Pleskovič; Paul Gamboa; León R Valdivieso; Hemal Gada; Gilbert H L Tang
Journal:  J Interv Cardiol       Date:  2021-04-28       Impact factor: 2.279

7.  Long-term clinical impact of permanent pacemaker implantation in patients undergoing transcatheter aortic valve implantation: a systematic review and meta-analysis.

Authors:  Andrea Zito; Giuseppe Princi; Marco Lombardi; Domenico D'Amario; Rocco Vergallo; Cristina Aurigemma; Enrico Romagnoli; Gemma Pelargonio; Piergiorgio Bruno; Carlo Trani; Francesco Burzotta; Filippo Crea
Journal:  Europace       Date:  2022-07-21       Impact factor: 5.486

8.  Meta-analysis of randomised trials compares mortality after transcatheter versus surgical aortic valve replacement.

Authors:  J Vendrik; J Baan
Journal:  Neth Heart J       Date:  2020-06       Impact factor: 2.380

9.  Influence of permanent pacemaker implantation after transcatheter aortic valve implantation with new-generation devices.

Authors:  B Gonska; M Keßler; J Wöhrle; W Rottbauer; J Seeger
Journal:  Neth Heart J       Date:  2018-12       Impact factor: 2.380

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.