| Literature DB >> 27746641 |
Hyun-Min Seo1, Jung-In Kim2, Han-Saem Kim2, Young-Jun Choi2, Won-Serk Kim2.
Abstract
BACKGROUND: Rosacea treatments including oral/topical medications and laser therapy are numerous but unsatisfactory.Entities:
Keywords: Alexandrite; Lasers; Neodymium; Rosacea
Year: 2016 PMID: 27746641 PMCID: PMC5064191 DOI: 10.5021/ad.2016.28.5.607
Source DB: PubMed Journal: Ann Dermatol ISSN: 1013-9087 Impact factor: 1.444
Fig. 1Flow diagram according to CONSORT guidelines showing the flow of subjects in the trial. PDL: 585-nm pulsed dye laser, LPAN: dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium: yttrium-aluminum-garnet laser.
Demographics and clinical characteristics of the study subjects
| Characteristic | PDL (n=19) | LPAN (n=18) | |
|---|---|---|---|
| Age (yr) | 48.6±11.3 | 49.9±12.8 | 0.733 |
| Male | 11 (57.9) | 8 (44.4) | 0.413 |
| Rosacea duration (yr) | 11.0±15.4 | 7.5±9.7 | 0.416 |
| Rosacea severity | 0.384 | ||
| Mild | 11 (57.9) | 14 (77.8) | |
| Moderate | 4 (21.1) | 3 (16.7) | |
| Severe | 4 (21.1) | 1 (5.6) | |
| Baseline erythema index | 18.1±3.8 | 17.3±2.3 | 0.433 |
Values are presented as mean±standard deviation or number (%). PDL: 585-nm pulsed dye laser, LPAN: dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium:yttrium-aluminum-garnet laser.
Erythema index results with pairwise comparisons between time periods
| Before treatment | Short-term follow-up | Long-term follow-up | Between baseline and short-term follow-up | Between baseline and long-term follow-up | |||
|---|---|---|---|---|---|---|---|
| Difference in means | Difference in means | ||||||
| LPAN | 17.3±2.3 | 16.0±2.6 | 16.7±2.4 | 1.36±1.23 | <0.001 | 0.63±1.16 | 0.035 |
| PDL | 18.1±3.8 | 17.2±4.2 | 17.6±3.4 | 0.96±1.20 | 0.003 | 0.51±1.70 | 0.206 |
Values are presented as mean±standard deviation. LPAN: dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium: yttrium-aluminum-garnet laser, PDL: 585-nm pulsed dye laser. Short-term follow up: 2-week after the last treatment, long-term follow up: 6-month after the last treatment.
Fig. 2(A~C) Male patient. (A) Before treatment, (B) at 2 weeks after four 585-nm pulsed dye laser (PDL) treatments, (C) at 6 months after last treatment. (D~F) Female patient. (D) Before treatment, (E) after four PDL treatments, (F) at 6-month after final treatment.
Fig. 3(A~C) Male patient. (A) Before treatment, (B) at 2 weeks after four dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium:yttrium-aluminum-garnet laser (LPAN) treatments, (C) at 6 months after last treatment. (D~F) Female patient. (D) Before treatment, (E) after four LPAN treatments, (F) at 6 months after final treatment.
Proportion of the physician's global assessment
| Physician’s global assessment | LPAN (n=18) | PDL (n=19) | ||
|---|---|---|---|---|
| Short-term follow-up | Long-term follow-up | Short-term follow-up | Long-term follow-up | |
| Worse | 3 (16.7) | 1 (5.6) | 6 (31.6) | 2 (10.5) |
| No change | 6 (33.3) | 1 (5.6) | 0 | 0 |
| Improved | 7 (38.9) | 8 (44.4) | 9 (47.4) | 7 (36.8) |
| Much improved | 2 (11.1) | 8 (44.4) | 4 (21.1) | 10 (52.6) |
Values are presented as number (%). LPAN: dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium: yttrium-aluminum-garnet laser, PDL: 585-nm pulsed dye laser. Short-term follow up: 2-week after the last treatment, long-term follow up: 6-month after the last treatment.
Fig. 4Subjective satisfaction assessment for the treatments. *No significant difference in the proportion of good or excellent between both treatments (p=0.842). PDL: 585-nm pulsed dye laser, LPAN: dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium:yttrium-aluminum-garnet laser.
Adverse effects
| Adverse effect | LPAN | PDL | |
|---|---|---|---|
| Erythema | 12 (66.7) | 10 (52.6) | 0.385 |
| Crusts | 2 (11.1) | 6 (31.6) | 0.232 |
| Hyperpigmentation | 1 (5.6) | 1 (5.3) | 1.000 |
| Vesicles | 0 (0.0) | 5 (26.3) | 0.046 |
| Dryness | 4 (22.2) | 3 (15.8) | 1.000 |
| Itching sense | 6 (33.3) | 3 (15.8) | 0.269 |
| Tightening sense | 4 (22.2) | 6 (31.6) | 0.714 |
Values are presented as number (%). LPAN: dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium:yttrium-aluminum-garnet laser, PDL: 585-nm pulsed dye laser.