Michiel S Oerbekke1, Mirelle J Stukstette1, Kurt Schütte2, Rob A de Bie3, Martijn F Pisters4, Benedicte Vanwanseele5. 1. Physical Therapy Research, Department of Rehabilitation, Nursing Science and Sport, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands; Center for Physical Therapy Research and Innovation in Primary Care, Julius Health Care Centers, The Netherlands. 2. Department of Kinesiology, Faculty of Kinesiology and Rehabilitation Sciences, KU Leuven, Leuven, Belgium; Department of Sport Science, Stellenbosch University, Stellenbosch, South Africa. 3. Department of Epidemiology, CAPHRI School for Public Health and Primary Care, Maastricht University, Maastricht, The Netherlands. 4. Physical Therapy Research, Department of Rehabilitation, Nursing Science and Sport, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands; Center for Physical Therapy Research and Innovation in Primary Care, Julius Health Care Centers, The Netherlands; Department of Health Innovation and Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands. 5. Department of Kinesiology, Faculty of Kinesiology and Rehabilitation Sciences, KU Leuven, Leuven, Belgium; Department of Health Innovation and Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands. Electronic address: benedicte.vanwanseele@faber.kuleuven.be.
Abstract
BACKGROUND: The OpenGo seems promising to take gait analysis out of laboratory settings due to its capability of long-term measurements and mobility. However, the OpenGo's concurrent validity and reliability need to be assessed to determine if the instrument is suitable for validation in patient samples. METHODS: Twenty healthy volunteers participated. Center of pressure data were collected under eyes open and closed conditions with participants performing unilateral stance trials on the gold standard (AMTI OR6-7 force plate) while wearing the OpenGo. Temporal gait data (stance time, gait cycle time, and cadence) were collected at a self-selected comfortable walking speed with participants performing test-retest trials on an instrumented treadmill while wearing the OpenGo. Validity was assessed using Bland-Altman plots. Reliability was assessed with Intraclass Correlation Coefficient (2,1) and smallest detectable changes were calculated. FINDINGS: Negative means of differences were found in all measured parameters, illustrating lower scores for the OpenGo on average. The OpenGo showed negative upper limits of agreement in center of pressure parameters on the mediolateral axis. Temporal reliability ICCs ranged from 0.90-0.93. Smallest detectable changes for both stance times were 0.04 (left) and 0.05 (right) seconds, for gait cycle time 0.08s, and for cadence 4.5 steps per minute. INTERPRETATION: The OpenGo is valid and reliable for the measurement of temporal gait parameters during walking. Measurements of center of pressure parameters during unilateral stance are not considered valid. The OpenGo seems a promising instrument for clinically screening and monitoring temporal gait parameters in patients, however validation in patient populations is needed. Copyright Â
BACKGROUND: The OpenGo seems promising to take gait analysis out of laboratory settings due to its capability of long-term measurements and mobility. However, the OpenGo's concurrent validity and reliability need to be assessed to determine if the instrument is suitable for validation in patient samples. METHODS: Twenty healthy volunteers participated. Center of pressure data were collected under eyes open and closed conditions with participants performing unilateral stance trials on the gold standard (AMTI OR6-7 force plate) while wearing the OpenGo. Temporal gait data (stance time, gait cycle time, and cadence) were collected at a self-selected comfortable walking speed with participants performing test-retest trials on an instrumented treadmill while wearing the OpenGo. Validity was assessed using Bland-Altman plots. Reliability was assessed with Intraclass Correlation Coefficient (2,1) and smallest detectable changes were calculated. FINDINGS: Negative means of differences were found in all measured parameters, illustrating lower scores for the OpenGo on average. The OpenGo showed negative upper limits of agreement in center of pressure parameters on the mediolateral axis. Temporal reliability ICCs ranged from 0.90-0.93. Smallest detectable changes for both stance times were 0.04 (left) and 0.05 (right) seconds, for gait cycle time 0.08s, and for cadence 4.5 steps per minute. INTERPRETATION: The OpenGo is valid and reliable for the measurement of temporal gait parameters during walking. Measurements of center of pressure parameters during unilateral stance are not considered valid. The OpenGo seems a promising instrument for clinically screening and monitoring temporal gait parameters in patients, however validation in patient populations is needed. Copyright Â
Authors: Maxime St-Georges; Alisson R Teles; Oded Rabau; Neil Saran; Jean A Ouellet; Catherine E Ferland Journal: BMC Musculoskelet Disord Date: 2020-07-16 Impact factor: 2.362
Authors: Alexander Maximilian Eickhoff; Raffael Cintean; Carina Fiedler; Florian Gebhard; Konrad Schütze; Peter H Richter Journal: Arch Orthop Trauma Surg Date: 2020-09-03 Impact factor: 3.067