Literature DB >> 27744176

Robust HPLC-MS/MS method for levofloxacin and ciprofloxacin determination in human prostate tissue.

O Szerkus1, J Jacyna1, A Gibas2, M Sieczkowski2, D Siluk1, M Matuszewski2, R Kaliszan1, M J Markuszewski3.   

Abstract

Fluoroquinolones are the drugs of choice in the prevention of bacterial infections after transrectal ultrasound guided prostate biopsy. In order to improve assessment of antibacterial efficacy in the target tissue a simple, selective, rapid and robust HPLC-ESI-MS/MS method for the determination of levofloxacin and ciprofloxacin concentrations in human prostate bioptates was developed and validated. Preparation procedure for prostate samples (10mg) was carried out using homogenization and filtration steps. Analyses were performed within 3.5min using RP C18 column in the isocratic elution mode with mobile phase composed of a mixture of 0.1% formic acid aqueous solution and 0.1% formic acid methanol solution (v/v; 79:21). The method was linear between 0.3μg/g and 15μg/g for levofloxacin and ciprofloxacin with coefficient of correlation (r) ≥0.999. The limit of detection and the limit of quantification for levofloxacin were 0.06μg/g and 0.2μg/g and for ciprofloxacin were 0.04μg/g and 0.13μg/g, respectively. Average concentrations (±SD) of levofloxacin and ciprofloxacin obtained from patients tissue were 5.4±2.2μg/g and 3.9±1.5μg/g, respectively. Additionally, during validation procedure a novel, experimental design approach was applied for the robustness study. For evaluation of analytical method robustness, Plackett-Burman design was employed and for sample preparation method robustness Fractional Factorial design was used. The developed and validated method was successfully applied to examine prostate tissue samples obtained from patients enrolled into a clinical study. Up to now, there has been no other HPLC-ESI-MS/MS method reported for the simultaneous determination of levofloxacin and ciprofloxacin in human prostatic tissue.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ciprofloxacin; Design of experiments; Levofloxacin; Mass spectrometry; Method validation; Prostate tissue

Mesh:

Substances:

Year:  2016        PMID: 27744176     DOI: 10.1016/j.jpba.2016.10.008

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

1.  Microwave-assisted synthesis of highly luminescent N- and S-co-doped carbon dots as a ratiometric fluorescent probe for levofloxacin.

Authors:  Huiyu Li; Yuan Xu; Jie Ding; Li Zhao; Tianyu Zhou; Hong Ding; Yanhua Chen; Lan Ding
Journal:  Mikrochim Acta       Date:  2018-01-10       Impact factor: 5.833

2.  Batch injection analysis with amperometric detection for fluoroquinolone determination in urine, pharmaceutical formulations, and milk samples using a reduced graphene oxide-modified glassy carbon electrode.

Authors:  Lucas Vinícius de Faria; Davi Marques de Farias; Thalles Pedrosa Lisboa; Maria Auxiliadora Costa Matos; Rodrigo Alejandro Abarza Munoz; Renato Camargo Matos
Journal:  Anal Bioanal Chem       Date:  2021-04-22       Impact factor: 4.142

3.  Polyvinyl Chloride Modified Carbon Paste Electrodes for Sensitive Determination of Levofloxacin Drug in Serum, Urine, and Pharmaceutical Formulations.

Authors:  Fatehy M Abdel-Haleem; Sonia Mahmoud; Nour Eldin T Abdel-Ghani; Rasha Mohamed El Nashar; Mikhael Bechelany; Ahmed Barhoum
Journal:  Sensors (Basel)       Date:  2021-05-01       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.