Estimation of fetal weight in pregnancies past term.

Torbjørn M Eggebø1,2,3, Olav A Klefstad1, Inger Økland1, Elsa Lindtjørn1, Sturla H Eik-Nes2,3, Håkon K Gjessing4,5.   

Abstract

INTRODUCTION: The aim of the study was to investigate the accuracy of estimating fetal weight with ultrasound in pregnancies past term, using the eSnurra algorithm.
MATERIAL AND METHODS: In all, 419 women with pregnancy length of 290 days, attending a specialist consultation at Stavanger University Hospital, Norway, were included in a prospective observational study. Fetal weight was estimated using biparietal diameter (BPD) and abdominal circumference (AC). The algorithm implemented in an electronic calculation (eSnurra) was used to compute estimated fetal weight (EFW). Results were compared with birthweight (BW).
RESULTS: The mean interval between the ultrasound examination and birth was 2 days (SD 1.4). The median difference between BW and EFW was -6 g (CI -40 to +25 g) and the median percentage error was -0.1% (95% CI -1.0 to 0.6%). The median absolute difference was 190 g (95% CI 170-207 g). The BW was within 10% of EFW in 83% (95% CI 79-87%) of cases and within 15% of EFW in 94% (95% CI 92-96%) of cases. Limits of agreement (95%) were from -553 g to +556 g. Using 5% false-positive rates, the sensitivity in detecting macrosomic and small for gestational age fetuses was 54% (95% CI 35-72%) and 49% (95% CI 35-63%), respectively.
CONCLUSION: The accuracy of fetal weight estimation was good. Clinicians should be aware of limitations related to prediction at the upper and lower end, and the importance of choosing appropriate cut-off levels.
© 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

Entities:  

Keywords:  Ultrasound; delivery; prenatal diagnosis

Mesh:

Year:  2016        PMID: 27743479     DOI: 10.1111/aogs.13044

Source DB:  PubMed          Journal:  Acta Obstet Gynecol Scand        ISSN: 0001-6349            Impact factor:   3.636


  2 in total

1.  Accuracy of immediate antepartum ultrasound estimated fetal weight and its impact on mode of delivery and outcome - a cohort analysis.

Authors:  Johannes Stubert; Adam Peschel; Michael Bolz; Änne Glass; Bernd Gerber
Journal:  BMC Pregnancy Childbirth       Date:  2018-05-02       Impact factor: 3.007

2.  Correlation of Ultrasonographic Estimation of Fetal Weight with Actual Birth Weight as Seen in a Private Specialist Hospital in South East Nigeria.

Authors:  Chisolum Ogechukwu Okafor; Charles Ikechukwu Okafor; Ikechukwu Innocent Mbachu; Izuchukwu Christian Obionwu; Michael Echeta Aronu
Journal:  Int J Reprod Med       Date:  2019-10-27
  2 in total