Literature DB >> 2774315

A parametric axisymmetric model study on the interface motions in porous-surfaced tibial implants.

A Shirazi-Adl1, A M Ahmed.   

Abstract

The effects of a number of variables on the interface relative motions in porous-surfaced tibial implants are investigated using a simplified axisymmetric finite element model. The parameters considered are contact or link spacing, height of the central metal stem, presence of a circumferential metal flange, presence of a UHMWP articular plate resting freely on or fixed to the metal base, resting of the prosthesis edge on the cortical shell, and type of the metal alloy. In order to represent the immediate post-surgical situation with no bone ingrowth, the interface between the bone and porous-surfaced metal is modelled by frictionless rigid links oriented normal to the interface. Cases are also studied in which the horizontal interface is assumed to be fixed while the vertical interface remains frictionless. The magnitudes of the interface motion are negligibly affected by the variation in the link spacing from 0.3 mm to about 3.0 mm. The interface relative motion is predicted to decrease in cases with a shorter central metal stem, with the addition of a circumferential metal flange, with the use of more rigid prosthesis, and with the addition of a UHMWP articular plate.

Entities:  

Mesh:

Year:  1989        PMID: 2774315     DOI: 10.1007/BF02368059

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  15 in total

1.  Observations on the effect of movement on bone ingrowth into porous-surfaced implants.

Authors:  R M Pilliar; J M Lee; C Maniatopoulos
Journal:  Clin Orthop Relat Res       Date:  1986-07       Impact factor: 4.176

2.  Effect of stress on tissue ingrowth into porous aluminum oxide.

Authors:  S F Hulbert; J R Matthews; J J Klawitter; B W Sauer; R B Leonard
Journal:  J Biomed Mater Res       Date:  1974

3.  Total knee arthroplasty in 1984.

Authors:  T R Waugh
Journal:  Clin Orthop Relat Res       Date:  1985 Jan-Feb       Impact factor: 4.176

4.  A comparative evaluation of tibial component designs of total knee prostheses.

Authors:  J L Lewis; M J Askew; D P Jaycox
Journal:  J Bone Joint Surg Am       Date:  1982-01       Impact factor: 5.284

5.  Radiographic and morphologic studies of load-bearing porous-surfaced structured implants.

Authors:  R M Pilliar; H U Cameron; R P Welsh; A G Binnington
Journal:  Clin Orthop Relat Res       Date:  1981-05       Impact factor: 4.176

6.  The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone.

Authors:  J D Bobyn; R M Pilliar; H U Cameron; G C Weatherly
Journal:  Clin Orthop Relat Res       Date:  1980 Jul-Aug       Impact factor: 4.176

7.  Effect of a cement-bone composite layer and prosthesis geometry on stresses in a prosthetically resurfaced tibia.

Authors:  S C Shrivastava; A M Ahmed; A Shirazi-Adl; D L Burke
Journal:  J Biomed Mater Res       Date:  1982-11

8.  Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants.

Authors:  P Ducheyne; P De Meester; E Aernoudt
Journal:  J Biomed Mater Res       Date:  1977-11

9.  Human histology of the bone-porous metal implant interface.

Authors:  J D Bobyn; C A Engh
Journal:  Orthopedics       Date:  1984-09-01       Impact factor: 1.390

10.  Noncemented total knee arthroplasty.

Authors:  G C Landon; J O Galante; M M Maley
Journal:  Clin Orthop Relat Res       Date:  1986-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.