Literature DB >> 27741084

Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear.

Vicente Compañ1, Marcel Aguilella-Arzo, Timothy B Edrington, Barry A Weissman.   

Abstract

PURPOSE: The main goal of this current work is to use an updated calculation paradigm, and updated boundary conditions, to provide theoretical guidelines to assist the clinician whose goal is to improve his or her scleral gas permeable (GP) contact lens wearing patients' anterior corneal oxygen supply.
METHODS: Our model uses a variable value of corneal oxygen consumption developed through Monod equations that disallows negative oxygen tensions within the stroma to predict oxygen tension at the anterior corneal surface of scleral GP contact lens wearing eyes, and to describe oxygen tension and flux profiles, for various boundary conditions, through the lens, tears, and cornea. We use several updated tissue and boundary parameters in our model. Tear exchange with GP scleral lenses is considered nonexistent in this model.
RESULTS: The majority of current scleral GP contact lenses should produce some levels of corneal hypoxia under open eye conditions. Only lenses producing the thinnest of tear vaults should result in anterior corneal surface oxygen tensions greater than a presumed critical oxygen tension of 100 mmHg. We also find that corneal oxygen tension and flux are each more sensitive to modification in tear vault than to changes in lens oxygen permeability, within the ranges of current clinical manipulation.
CONCLUSIONS: Our study suggests that clinicians would be prudent to prescribe scleral GP lenses manufactured from higher oxygen permeability materials and especially to fit without excessive corneal clearance.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27741084     DOI: 10.1097/OPX.0000000000000988

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  2 in total

1.  A refined model on flow and oxygen consumption in the human cornea depending on the oxygen tension at the interface cornea/post lens tear film during contact lens wear.

Authors:  Vicente Compañ Moreno; Marcel Aguilella-Arzo; Roxana M Del Castillo; Francisco J Espinós; Luis Felipe Del Castillo
Journal:  J Optom       Date:  2021-02-13

2.  Identification of Leukocytes Associated With Midday Fogging in the Post-Lens Tear Film of Scleral Contact Lens Wearers.

Authors:  Cameron K Postnikoff; Andrew D Pucker; John Laurent; Carrie Huisingh; Gerald McGwin; Jason J Nichols
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-01-02       Impact factor: 4.799

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.