Literature DB >> 27740643

The Impact of Conical and Nonconical Abutments on Bacterial Infiltration at the Implant-Abutment Interface.

Elen Guerra, Cristiane Pereira, Renata Faria, Antonio Olavo Jorge, Marco Antonio Bottino, Renata Marques de Melo.   

Abstract

This study evaluated the in vitro bacterial microleakage at the implant-abutment interface of three prosthetic connections: external (EH) and internal hexagon (IH) and taper connection (TC: solid [ST], taper with internal hexagon [IT], and short taper [OT]). Escherichia coli (E coli) and Streptococcus sanguinis (S sanguinus) were inoculated in the apical portion of the abutment screw, which was immersed in sterile brain-heart infusion broth for 14 days. There were no differences between the percentages of bacterial infiltration for IH (9.09%), ST (21.74%), IT (22.73%), and OT (11.11%). EH did not present viable bacteria. There were no significant differences in the counts of connections inoculated and not infiltrated by E coli or S sanguinis nor in those infiltrated by both bacteria (one-way analysis of variance, P < .05). Except for EH, all implant designs and abutments showed bacteria that were capable of surviving and causing infiltration.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27740643     DOI: 10.11607/prd.2779

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  4 in total

Review 1.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

2.  Bacterial Microleakage at the Implant-Abutment Interface: An In Vitro Study.

Authors:  Simonetta D'Ercole; Tatiane Cristina Dotta; Marzieh Ramezani Farani; Niloofar Etemadi; Giovanna Iezzi; Luca Comuzzi; Adriano Piattelli; Morena Petrini
Journal:  Bioengineering (Basel)       Date:  2022-06-26

3.  Bacterial infiltration and detorque at the implant abutment morse taper interface after masticatory simulation.

Authors:  Ana Paula Granja Scarabel Nogueira Bella; Alessandra Sayuri Tuzita; Ivana Barbosa Suffredini; Alberto Noriyuki Kojima; Elcio Magdalena Giovani; Alfredo Mikail Melo Mesquita
Journal:  Sci Rep       Date:  2022-10-12       Impact factor: 4.996

4.  Effects of Aging Torque Controllers on Screw Tightening Force and Bacterial Micro-Leakage on the Implant-Abutment Complex.

Authors:  Yousef Jiries; Tamar Brosh; Shlomo Matalon; Vladimir Perlis; Zeev Ormianer
Journal:  Materials (Basel)       Date:  2022-01-14       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.