Literature DB >> 27740477

4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography.

Douglas Wildes, Warren Lee, Bruno Haider, Scott Cogan, Krishnakumar Sundaresan, David M Mills, Christopher Yetter, Patrick H Hart, Christopher R Haun, Mikael Concepcion, Johan Kirkhorn, Marc Bitoun.   

Abstract

We developed a 2.5 ×6.6 mm 2 2 -D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm 2 area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 ° ×60 ° ×8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.

Entities:  

Mesh:

Year:  2016        PMID: 27740477     DOI: 10.1109/TUFFC.2016.2615602

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  10 in total

1.  Co-Integrated PIN-PMN-PT 2-D Array and Transceiver Electronics by Direct Assembly Using a 3-D Printed Interposer Grid Frame.

Authors:  Robert Wodnicki; Haochen Kang; Ruimin Chen; Nestor E Cabrera-Munoz; Hayong Jung; Laiming Jiang; Josquin Foiret; Yu Liu; Victoria Chiu; Douglas N Stephens; Qifa Zhou; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-30       Impact factor: 2.725

Review 2.  Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions.

Authors:  Craig Basman; Yuvrajsinh J Parmar; Itzhak Kronzon
Journal:  Curr Cardiol Rep       Date:  2017-09-06       Impact factor: 2.931

3.  Cardiac Lesion Mapping In Vivo Using Intracardiac Myocardial Elastography.

Authors:  Ethan Bunting; Clement Papadacci; Elaine Wan; Vincent Sayseng; Julien Grondin; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-01       Impact factor: 2.725

4.  A Reduced-Wire ICE Catheter ASIC With Tx Beamforming and Rx Time-Division Multiplexing.

Authors:  Gwangrok Jung; Coskun Tekes; M Wasequr Rashid; Thomas M Carpenter; David Cowell; Steven Freear; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2018-11-16       Impact factor: 3.833

Review 5.  Current Ultrasound Technologies and Instrumentation in the Assessment and Monitoring of COVID-19 Positive Patients.

Authors:  Xuejun Qian; Robert Wodnicki; Haochen Kang; Junhang Zhang; Hisham Tchelepi; Qifa Zhou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-08-28       Impact factor: 2.725

Review 6.  Advances in Capacitive Micromachined Ultrasonic Transducers.

Authors:  Kevin Brenner; Arif Sanli Ergun; Kamyar Firouzi; Morten Fischer Rasmussen; Quintin Stedman; Butrus Pierre Khuri-Yakub
Journal:  Micromachines (Basel)       Date:  2019-02-23       Impact factor: 2.891

7.  Sensitivity Enhanced Photoacoustic Imaging Using a High-Frequency PZT Transducer with an Integrated Front-End Amplifier.

Authors:  Chen Yang; Xiaohua Jian; Xinle Zhu; Jiabing Lv; Yang Jiao; Zhile Han; Antonios Stylogiannis; Vasilis Ntziachristos; George Sergiadis; Yaoyao Cui
Journal:  Sensors (Basel)       Date:  2020-01-30       Impact factor: 3.576

8.  Highly Integrated Multiplexing and Buffering Electronics for Large Aperture Ultrasonic Arrays.

Authors:  Robert Wodnicki; Haochen Kang; Di Li; Douglas N Stephens; Hayong Jung; Yizhe Sun; Ruimin Chen; Lai-Ming Jiang; Nestor E Cabrera-Munoz; Josquin Foiret; Qifa Zhou; Katherine W Ferrara
Journal:  BME Front       Date:  2022-06-30

9.  Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves.

Authors:  Emmanuel Roux; François Varray; Lorena Petrusca; Christian Cachard; Piero Tortoli; Hervé Liebgott
Journal:  Sci Rep       Date:  2018-06-14       Impact factor: 4.379

10.  Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation.

Authors:  Jian-Chiun Liou; Chih-Wei Peng; Zhen-Xi Chen
Journal:  Micromachines (Basel)       Date:  2021-03-30       Impact factor: 2.891

  10 in total