Non-Newtonian Blood Flow Simulation of Diastolic Phase in Bileaflet Mechanical Heart Valve Implanted in a Realistic Aortic Root Containing Coronary Arteries.

Pedram Hanafizadeh1, Nima Mirkhani2, Mohammad Reza Davoudi3, Mahtab Masouminia2, Keyvan Sadeghy2.   

Abstract

Coronary arteries, which are branched from the sinuses, have tangible effects on the hemodynamic performance of the bileaflet mechanical heart valve (BMHV), especially in the diastolic phase. To better understand this issue, a computer model of ascending aorta including realistic sinus shapes and coronary arteries has been generated in this study in order to investigate the BMHV performance during diastole. Three-dimensional transient numerical analysis is conducted to simulate the diastolic blood flow through the hinges and in coronary arteries under the assumption of non-Newtonian behavior. Results indicate that as blood flows to the coronary arteries mainly during diastole, leakage flow from the hinge and other gaps will change considering the influence of coronary arteries. In addition, BMHV in the case of aortic replacement will increase blood flow rate into the coronary arteries about 100% as the mechanical valve resistance is higher than a native heart valve. Also, it will change the wall shear stress (WSS) distribution and increase coronary artery disease (CAD) potential. It is found out that although less leakage flow reduces the velocity magnitudes through the gaps, the shear stress acting on blood elements with non-Newtonian assumption will be detrimental in the hinge corner at the ventricular side. High WSS of 1800 Pa is observed at beginning of diastole at this region.
© 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Bileaflet mechanical heart valve; Coronary arteries; Diastolic phase; Non-Newtonian; Numerical simulation

Mesh:

Year:  2016        PMID: 27739601     DOI: 10.1111/aor.12787

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  2 in total

Review 1.  Simulation of Mechanical Heart Valve Dysfunction and the Non-Newtonian Blood Model Approach.

Authors:  Aolin Chen; Adi Azriff Bin Basri; Norzian Bin Ismail; Masaaki Tamagawa; Di Zhu; Kamarul Arifin Ahmad
Journal:  Appl Bionics Biomech       Date:  2022-04-19       Impact factor: 1.664

2.  Transient numerical simulation of the right coronary artery originating from the left sinus and the effect of its acute take-off angle on hemodynamics.

Authors:  Mengyang Cong; Huihui Zhao; Shun Dai; Chuanzhi Chen; Xingming Xu; Jianfeng Qiu; Shengxue Qin
Journal:  Quant Imaging Med Surg       Date:  2021-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.