| Literature DB >> 27722199 |
Leily Macedo Firoozmand1, Mariana Gonçalves Cordeiro2, Marcos André Dos Santos Da Silva3, Rudys Rodolfo De Jesus Tavarez4, Etevaldo Matos Maia Filho3.
Abstract
The aim of this study was to evaluate the radiopacity of silorane and methacrylate resin composites, comparing them to the enamel, dentin, and aluminum penetrometer using a digital image. From six resin composites (Filtek™ P90, Filtek Z350, Filtek Z350 XT flow, Tetric Ceram, TPH Spectrum, and SureFil SDR flow) cylindrical disks (5 × 1 mm) were made and radiographed by a digital method, together with a 15-step aluminum step-wedge and a 1 mm slice of human tooth. The degree of radiopacity of each image was quantified using digital image processing. The mean values of the shades of gray of the tested materials were measured and the equivalent width of aluminum was calculated for each resin. The results of our work yielded the following radiopacity values, given here in descending order: Tetric Ceram > TPH > SDR > Z350 > Z350 flow > P90 > enamel > dentin. The radiopacity of the materials was different both for the enamel and for the dentin, except for resin P90, which was no different than enamel. In conclusion, silorane-based resin exhibited a radiopacity higher than dentin and closest to the enamel; a large portion of the methacrylate-based flow and conventional resins demonstrated greater radiopacity in comparison to dentin and enamel.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27722199 PMCID: PMC5046049 DOI: 10.1155/2016/6389347
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
Materials and characteristics.
| Group | Composite resin | Commercial brand | Composition | Lot |
|---|---|---|---|---|
| G1 | Filtek P90 | 3M/ESPE, St. Paul, MN, USA | Microhybrid | N322267 |
|
| ||||
| G2 | Filtek Z350 | 3M/ESPE, St. Paul, MN, USA | Nanoparticles and nanoclusters | N355898 |
|
| ||||
| G3 | Filtek Z350 XT flow | 3M/ESPE, St. Paul, MN, USA | Nanoparticles and nanoclusters | N399586 |
|
| ||||
| G4 | Tetric Ceram | Ivoclar-Vivadent, Schaan, Liechtenstein | Microhybrid | P87674 |
|
| ||||
| G5 | TPH Spectrum | Dentsply Caulk, Milford, DE, USA | Microhybrid | 720359E |
|
| ||||
| G6 | SureFil SDR flow | Dentsply Caulk, Milford, DE, USA | (Bis-GMA/TEGDMA) | 671513E |
Figure 1Radiographic image of resin samples ((a) P90, (b) Z350, (c) Z350 flow, (d) Tetric Ceram, (e) TPH, (f) SDR), slice of human tooth (g), and aluminum step-wedge (h).
Radiopacity (shades of gray) and the aluminum equivalent in millimeters (mm Al) of the different materials evaluated.
| Mean gray | Radiopacity value (mm Al equivalent) | |
|
| ||
| Tetric Ceram | 84.20 (±9.68)A | 3.10 (±0.32)x,y |
| TPH | 72.20 (±7.05)B | 2.65 (±0.31)x,y |
| SDR | 52.60 (±3.51)CD | 1.94 (±0.14)x,y |
| Z350 | 48.20 (±2.77)DE | 1.78 (±0.12)x,y |
| Z350 flow | 38.40 (±3.97)E | 1.44 (±0.16)x,y |
| P90 | 25.60 (±1.00)F | 0.99 (±0.12)y |
|
| ||
| Enamel | 22.60 (±5.86) | 0.91 (±0.22) |
| Dentin | 14.20 (±2.28) | 0.63 (±0.12) |
Different letters: significant difference between resins, p < 0.05 (ANOVA-Tukey test).
Significant difference for the enamel (x) and dentin (y), p < 0.05 (ANOVA-Dunnett's test).
No significant difference for the 1 mm Al, p > 0.05 (one-sample t-test).