Literature DB >> 27720604

The electro/Fe3+/peroxydisulfate (PDS) process coupled to activated sludge culture for the degradation of tetracycline.

Amina Ledjeri1, Idris Yahiaoui2, Farida Aissani-Benissad1.   

Abstract

The removal of tetracycline (TC) by electro/Fe3+/peroxydisulfate process combined to the biological treatment is reported in this study. Effect of current density, peroxydisulfate (PDS) concentration, Fe3+ ions concentration and initial tetracycline concentration were investigated. The results indicated that the removal efficiency of TC increased with increasing current density and decreases with tetracycline initial concentration. This effect is attributed to the competition of TC and electrogenerated intermediate compounds for the consumption of oxidizing SO4- radicals. The TC degradation efficiency was improved significantly when the PDS and Fe3+ concentrations increased from 1 to 10 mM and 1-2 mM, respectively. Above 10 mM PDS and 2 mM Fe3+ concentrations, a decrease of TC degradation efficiency was observed. The optimal operating conditions were: 2 mM Fe3+, 0.06 mM TC, 10 mM PDS concentrations and 40 mA cm-2 current density. Under these conditions a total degradation of TC within only 40 min of reaction time and 98% of mineralization yield after 3 h electrolysis were obtained. The biodegradability of the solution after electro/Fe3+/peroxydisulfate pre-treatment showed that BOD5/COD ratio increased from 0.00 initially to 0.42, 0.46 and 0.83 after 4 h, 5 h and 6 h, respectively, namely above the limit of biodegradability (0.4). The enhancement of biodegradability initially from 0.00 to 0.42 and 0.46 after 4 h and 5 h of electrolysis respectively, was confirmed by the biological treatment, since 77.51% and 92.54% of the dissolved organic carbon was removed respectively by coupling Electro/Fe3 +/PDS pre-treatment and a biological treatment.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Antibiotics; Biological treatment; Electrochemical oxidation; Ferric irons; Peroxydisulfate; Sulfate radicals; Tetracycline

Mesh:

Substances:

Year:  2016        PMID: 27720604     DOI: 10.1016/j.jenvman.2016.09.086

Source DB:  PubMed          Journal:  J Environ Manage        ISSN: 0301-4797            Impact factor:   6.789


  2 in total

1.  Removal of organic matter and nutrients from hospital wastewater by electro bioreactor coupled with tubesettler.

Authors:  Roohul Abad Khan; Rachida El Morabet; Nadeem A Khan; Sirajuddin Ahmed; Majed Alsubih; Nabisab Mujawar Mubarak; Mohammad Hadi Dehghani; Rama Rao Karri; Nooshin Zomorodiyan
Journal:  Sci Rep       Date:  2022-06-03       Impact factor: 4.996

2.  Performance of a Three-Dimensional Electrochemical Reactor (3DER) on Bisphenol A Degradation.

Authors:  Xu Ren; Kai Song; Qiaoyun Zhang; Linghan Xu; Zhuyi Yu; Peixin Tang; Zhicheng Pan
Journal:  Front Chem       Date:  2022-07-15       Impact factor: 5.545

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.