Literature DB >> 27720277

Dosimetric and radiobiological comparison of TG-43 and Monte Carlo calculations in 192Ir breast brachytherapy applications.

V Peppa1, E P Pappas1, P Karaiskos1, T Major2, C Polgár2, P Papagiannis3.   

Abstract

PURPOSE: To investigate the clinical significance of introducing model based dose calculation algorithms (MBDCAs) as an alternative to TG-43 in 192Ir interstitial breast brachytherapy.
MATERIALS AND METHODS: A 57 patient cohort was used in a retrospective comparison between TG-43 based dosimetry data exported from a treatment planning system and Monte Carlo (MC) dosimetry performed using MCNP v. 6.1 with plan and anatomy information in DICOM-RT format. Comparison was performed for the target, ipsilateral lung, heart, skin, breast and ribs, using dose distributions, dose-volume histograms (DVH) and plan quality indices clinically used for plan evaluation, as well as radiobiological parameters.
RESULTS: TG-43 overestimation of target DVH parameters is statistically significant but small (less than 2% for the target coverage indices and 4% for homogeneity indices, on average). Significant dose differences (>5%) were observed close to the skin and at relatively large distances from the implant leading to a TG-43 dose overestimation for the organs at risk. These differences correspond to low dose regions (<50% of the prescribed dose), being less than 2% of the prescribed dose. Detected dosimetric differences did not induce clinically significant differences in calculated tumor control probabilities (mean absolute difference <0.2%) and normal tissue complication probabilities.
CONCLUSION: While TG-43 shows a statistically significant overestimation of most indices used for plan evaluation, differences are small and therefore not clinically significant. Improved MBDCA dosimetry could be important for re-irradiation, technique inter-comparison and/or the assessment of secondary cancer induction risk, where accurate dosimetry in the whole patient anatomy is of the essence.
Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  (192)Ir; Brachytherapy; Breast; Dosimetry; MBDCA; TG-43

Mesh:

Substances:

Year:  2016        PMID: 27720277     DOI: 10.1016/j.ejmp.2016.09.020

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

Review 1.  A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy.

Authors:  Yousif A M Yousif; Alexander F I Osman; Mohammed A Halato
Journal:  Phys Eng Sci Med       Date:  2021-06-17

2.  Cytotoxicity, Inflammatory Activity, and Angiogenesis Are Induced by Different Silicone Implants.

Authors:  Rodrigo Bredariol Achilles; Daniel Vitor DE Souza; Hananiah Tardivo Quintana; Andrea Cristina Moraes Malinverni; Carolina Foot Gomes DE Moura; Giovana Wagner Branda; Ana Claudia Muniz Renno; Daniel Araki Ribeiro
Journal:  In Vivo       Date:  2022 May-Jun       Impact factor: 2.406

3.  A comparative assessment of inhomogeneity and finite patient dimension effects in 60Co and 192Ir high-dose-rate brachytherapy.

Authors:  Irina Fotina; Kyveli Zourari; Vasileios Lahanas; Evaggelos Pantelis; Panagiotis Papagiannis
Journal:  J Contemp Brachytherapy       Date:  2018-02-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.