Literature DB >> 27718484

Progress and impact of enzyme measurement standardization.

Ilenia Infusino, Erika Frusciante, Federica Braga, Mauro Panteghini.   

Abstract

International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has established reference measurement procedures (RMPs) for the most popular enzymes. Manufacturers should assign values to commercial calibrators traceable to these RMPs to achieve equivalent results in clinical samples, independent of reagent kits, instruments, and laboratory where the measurement is carried out. The situation is, however, far from acceptable. Some manufacturers continue to market assays giving results that are not traceable to internationally accepted RMPs. Meanwhile, end-users often do not abandon assays with demonstrated insufficient quality. Of the enzyme measurements, creatine kinase (CK) is satisfactorily standardized and a substantial improvement in performance of marketed γ-glutamyltranspeptidase (GGT) assays has been demonstrated. Conversely, aminotransferase measurements often exceed the desirable analytical performance because of the lack of pyridoxal-5-phosphate addition in the commercial reagents. Measurements of lactate dehydrogenase (LDH), alkaline phosphatase (ALP), and α-amylase (AMY) still show major disagreement, suggesting the need for improvement in implementing traceability to higher-order references. This is mainly the result of using assays with different analytical selectivities for these enzymes. The definition by laboratory professionals of the clinically acceptable measurement uncertainty for each enzyme together with the adoption by EQAS of commutable materials and use of an evaluation approach based on trueness represent the way forward for reaching standardization in clinical enzymology.

Entities:  

Mesh:

Year:  2017        PMID: 27718484     DOI: 10.1515/cclm-2016-0661

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  4 in total

1.  Association between lipid biomarkers and osteoporosis: a cross-sectional study.

Authors:  Bo Kan; Qianqian Zhao; Lijuan Wang; Shanshan Xue; Hanqing Cai; Shuman Yang
Journal:  BMC Musculoskelet Disord       Date:  2021-09-06       Impact factor: 2.362

2.  EQA/PT scheme to improve the equivalence of enzymatic results between mutual recognition laboratories in Beijing.

Authors:  Qing Tong; Shunli Zhang; Chang Zuo
Journal:  J Clin Lab Anal       Date:  2021-05-05       Impact factor: 2.352

3.  Standardization in laboratory medicine: Two years' experience from category 1 EQA programs in Spain.

Authors:  Carmen Ricós; Carmen Perich; Beatriz Boned; Elisabet González-Lao; Jorge Diaz-Garzón; Montserrat Ventura; Sandra Bullich; Zoraida Corte; Joana Minchinela; Fernando Marques; Margarita Simón; Virtudes Alvarez; José-Vicente García-Lario; Pilar Fernández-Fernández; Pilar Fernández-Calle
Journal:  Biochem Med (Zagreb)       Date:  2018-12-15       Impact factor: 2.313

4.  Aspartate aminotransferase in COVID-19: A probably overrated marker.

Authors:  Elena Aloisio; Mauro Panteghini
Journal:  Liver Int       Date:  2021-10-05       Impact factor: 5.828

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.