Hanif Esmail1,2,3, Friedrich Thienemann4,5, Tolu Oni4,6, Rene Goliath4, Katalin A Wilkinson4,7, Robert J Wilkinson4,8,7.
Abstract
BACKGROUND: HIV-1 infection impairs tuberculosis (TB) specific immune responses affecting the diagnosis of latent TB. We aimed to (1) determine the proportion of HIV-1-infected adults with a negative QuantiFERON®-TB Gold in-tube (QFT-GIT) and Tuberculin skin testing (TST) that convert to QFT-GIT positive following TST, and (2) evaluate the relationship between conversion and baseline QFT-GIT results.Entities:
Keywords: Diagnostics; HIV; Interferon Gamma Release Assay; Latent tuberculosis; QuantiFERON®-TB Gold in-tube
Mesh:
Year: 2016 PMID: 27717329 PMCID: PMC5055657 DOI: 10.1186/s12879-016-1875-6
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Table showing differences in characteristics between converters and non-converters
| Variable | Overall population | Converters | Non-converters |
|
|---|---|---|---|---|
| Age (years) – Med(IQR) | 33(29–40) | 32(29–40) | 36 (30–39) | 0.52 |
| Sex - Female | 90.9 % | 100 % | 84.6 % | 0.49 |
| CD4 count (/mm3) – Med(IQR) | 477 (439 – 621) | 466 (426–720) | 477 (458–589) | 0.87 |
| On ART | 73 % | 66.6 % | 76.9 % | 0.66 |
| Previous TB treatment | 31.8 % | 23.1 % | 44.4 % | 0.37 |
| Time between tests (days) – Med(IQR) | 62 (49–70) | 50 (46–62) | 69 (58–71) | 0.11 |
| Baseline TBAg-Nil (IU/ml) – Med (IQR) | 0.07 (0.01–0.21) | 0.21 (0.17–0.26) | 0.02 (0.01–0.07) | 0.002 |
| Change in TBAg-Nil (IU/ml) – Med(IQR) | 0.09 (−0.05–0.62) | 0.82 (0.39–1.28) | 0.03 (−0.05–0.06) | 0.0001 |
Characteristics of 9 converters and 13 non-converters compared. Gaussian distribution of data determined by Shapiro-Wilk test. Non-parametric data compared using Mann-Whitney U test and parametric data compared using t-test. Proportions were compared by χ 2 test or Fisher’s exact test (if the contingency included a number ≤ 5)
Med Median, IQR Interquartile range, ART Antiretroviral therapy, IU international units
Fig. 1Change in QFT-GIT TBAg-Nil before and after TST. Graph showing TBAg-Nil level for participants at baseline and after boosting. Values for individual participants connected with line. Values <0 IU/mL not shown on graph
Fig. 2ROC analysis. a. Figure showing ROC analysis for baseline TBAg-Nil to distinguish converters and non-converters. b Table showing sensitivity, specificity, proportion correctly classified, positive likelihood ratio and negative likelihood ratio for each cut-off value. LR + = positive likelihood ratio, LR- = negative likelihood ratio