Takeo Ishii1,2, Yasunobu Suzuki3, Takuji Nakayama3, Miki Ohmori3, Shinichi Masai3, Naru Sasagawa4, Kunio Ohyama1. 1. Zenjinkai Group, Internal Medicine, Yokohama-Daiichi Hospital, Yokohama, Kanagawa - Japan. 2. Department of Epidemiology and Public Health, Graduate School of Medicine, Yokohama City University, Yokohama, Kanagawa - Japan. 3. Zenjinkai Group, Department of Clinical Engineering, Surveillance Echo Team, Yokohama-Daiichi Hospital, Yokohama, Kanagawa - Japan. 4. Zenjinkai Group, Vascular Access Center, Yokohama-Daiichi Hospital, Yokohama, Kanagawa - Japan.
Abstract
OBJECTIVE: To determine if duplex ultrasound (US) for arteriovenous fistulas (AVFs) can predict vascular events (VEs; thrombosis and stenosis). METHODS: Duplex US was performed for vascular access evaluation in 2557 maintenance hemodialysis (HD) patients between October 1, 2013 and March 31, 2016. Of these patients, 2184 patients were finally included in this study. AVF dysfunction was assessed using the brachial artery blood flow volume (Qa; mL/min), arterial blood flow resistance index (RI), and residual diameter of the fistula vein (RD; mm). Proximal, midpoint, and distal aspects of the fistulas were measured. The baseline measurements were the US assessments, and the endpoint was VEs requiring vascular access intervention therapy or vascular surgery. Associations of US findings and VEs were assessed with receiver operating characteristic curve analysis, log-rank analysis, and multivariate Cox hazard models. RESULTS: The mean Qa was 772.8 ± 441.4 mL/min; RI, 0.56 ± 0.1; and RD, 2.37 ± 1.0 mm. The optimal Qa cut-off point was calculated as 581.5 mL/min, RI cut-off as 0.56, and RD cut-off as 1.85 mm. VEs were more frequent in patients with a Qa <581.5 mL/min than in those with a Qa >581.5 mL/min (p<0.001). In multivariate analysis, Qa, ferritin, transferrin saturation, and warfarin use were significantly associated with VEs. CONCLUSIONS: US evaluation of AVFs in HD patients is a simple method to predict the risks of thrombosis and fistula dysfunction. Qa, ferritin, transferrin saturation, and warfarin use might be associated with VEs.
OBJECTIVE: To determine if duplex ultrasound (US) for arteriovenous fistulas (AVFs) can predict vascular events (VEs; thrombosis and stenosis). METHODS: Duplex US was performed for vascular access evaluation in 2557 maintenance hemodialysis (HD) patients between October 1, 2013 and March 31, 2016. Of these patients, 2184 patients were finally included in this study. AVF dysfunction was assessed using the brachial artery blood flow volume (Qa; mL/min), arterial blood flow resistance index (RI), and residual diameter of the fistula vein (RD; mm). Proximal, midpoint, and distal aspects of the fistulas were measured. The baseline measurements were the US assessments, and the endpoint was VEs requiring vascular access intervention therapy or vascular surgery. Associations of US findings and VEs were assessed with receiver operating characteristic curve analysis, log-rank analysis, and multivariate Cox hazard models. RESULTS: The mean Qa was 772.8 ± 441.4 mL/min; RI, 0.56 ± 0.1; and RD, 2.37 ± 1.0 mm. The optimal Qa cut-off point was calculated as 581.5 mL/min, RI cut-off as 0.56, and RD cut-off as 1.85 mm. VEs were more frequent in patients with a Qa <581.5 mL/min than in those with a Qa >581.5 mL/min (p<0.001). In multivariate analysis, Qa, ferritin, transferrin saturation, and warfarin use were significantly associated with VEs. CONCLUSIONS: US evaluation of AVFs in HDpatients is a simple method to predict the risks of thrombosis and fistula dysfunction. Qa, ferritin, transferrin saturation, and warfarin use might be associated with VEs.