Literature DB >> 27714778

Meta-analysis of the use of surgical sealants for suture-hole bleeding in arterial anastomoses.

A C Rogers1, L P Turley1, K S Cross1, M P McMonagle1.   

Abstract

BACKGROUND: Suture-hole bleeding in arterial anastomoses prolongs operating time and increases blood loss, particularly with the use of prosthetic grafts. Surgical sealants (such as fibrin) may be used as haemostatic adjuncts in vascular surgery. This is a systematic review and meta-analysis of published studies that investigated the utility of surgical sealants in arterial-to-prosthetic graft anastomoses.
METHODS: A systematic review was undertaken of papers published until January 2015 on Embase, MEDLINE, PubMed, PubMed Central and Cochrane databases that analysed the use of surgical sealants as haemostatic adjuncts after arterial anastomoses. RCTs were included, with study endpoints of time to haemostasis or haemostasis at 5 min. Secondary outcomes included treatment failure, mean difference in estimated blood loss and duration of surgery. Sensitivity and subgroup analyses were performed, as well as funnel plot analysis for publication bias.
RESULTS: A total of 2513 citations were reviewed; 19 RCTs comprising 1560 patients were ultimately included in the analysis. The majority of studies compared fibrin sealant with control haemostatic measures. Pooled analysis suggested that surgical sealants reduced the time to haemostasis (mean difference 243·26 (95 per cent c.i. 183·99 to 302·53) s; P < 0·001), improved haemostasis at 5 min (odds ratio 4·50, 95 per cent c.i. 2·59 to 7·81; P < 0·001), and were associated with less treatment failure, blood loss and shorter duration of surgery.
CONCLUSION: Surgical sealants appear to reduce suture-hole bleeding significantly in vascular prosthetic graft anastomoses compared with standard haemostatic measures.
© 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27714778     DOI: 10.1002/bjs.10308

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  4 in total

1.  Analysis of the hemostatic potential of modern topical sealants on arterial and venous anastomoses: an experimental porcine study.

Authors:  Hamidreza Fonouni; Arash Kashfi; Ali Majlesara; Oliver Stahlheber; Lukas Konstantinidis; Thomas W Kraus; Arianeb Mehrabi; Hani Oweira
Journal:  J Mater Sci Mater Med       Date:  2017-07-28       Impact factor: 3.896

2.  Affimer proteins as a tool to modulate fibrinolysis, stabilize the blood clot, and reduce bleeding complications.

Authors:  Katherine J Kearney; Nikoletta Pechlivani; Rhodri King; Christian Tiede; Fladia Phoenix; Ramsah Cheah; Fraser L Macrae; Katie J Simmons; Iain W Manfield; Kerrie A Smith; Benjamin E J Spurgeon; Khalid M Naseem; Robert A S Ariens; Michael J McPherson; Darren C Tomlinson; Ramzi A Ajjan
Journal:  Blood       Date:  2018-12-13       Impact factor: 22.113

Review 3.  Heterologous fibrin sealant derived from snake venom: from bench to bedside - an overview.

Authors:  Rui Seabra Ferreira; Luciana Curtolo de Barros; Luciana Patrícia Fernandes Abbade; Silvia Regina Catharino Sartori Barraviera; Maria Regina Cavariani Silvares; Leticia Gomes de Pontes; Lucilene Delazari Dos Santos; Benedito Barraviera
Journal:  J Venom Anim Toxins Incl Trop Dis       Date:  2017-04-04

Review 4.  Comparison of fibrin sealants in peripheral vascular surgery: A systematic review and network meta-analysis.

Authors:  Walter Danker Iii; Ashley DeAnglis; Nicole Ferko; David Garcia; Andrew Hogan
Journal:  Ann Med Surg (Lond)       Date:  2020-12-09
  4 in total