| Literature DB >> 27707941 |
L Kristopher Siu1,2,3,4, Yu-Kuo Tsai1, Jung-Chung Lin3, Te-Li Chen5, Chang-Phone Fung5, Feng-Yee Chang6.
Abstract
In this study, a novel colloidal gold-based immunochromatographic strip (ICS) containing anti-Klebsiella pneumoniae capsular polysaccharide polyclonal antibodies was developed to specifically detect K. pneumoniae serotypes K1 and K2. Capsular polysaccharide K1 and K2 antigens were first used to produce polyclonal anti-K1 and anti-K2 antibodies. Reference strains with different serotypes, nontypeable K. pneumoniae strains, and other bacterial species were then used to assess the sensitivity and specificity of these test strips. The detection limit was found to be 105 CFU, and the ICSs were stable for 6 months when stored at room temperature. No false-positive or false-negative results were observed, and equivalent results were obtained compared to those of more conventional test methods, such as PCR or serum agglutination. In conclusion, the ICS developed here requires no technical expertise and allows for the specific, rapid, and simultaneous detection of K. pneumoniae serotypes K1 and K2.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27707941 PMCID: PMC5121394 DOI: 10.1128/JCM.01608-16
Source DB: PubMed Journal: J Clin Microbiol ISSN: 0095-1137 Impact factor: 5.948