Literature DB >> 27706525

Endoscopic treatment of post-laparoscopic sleeve gastrectomy leaks using a specifically designed metal stent.

Andrea Tringali1, Vincenzo Bove1, Vincenzo Perri1, Rosario Landi1, Pietro Familiari1, Ivo Boškoski1, Guido Costamagna1.   

Abstract

Background and study aim Leakage of the surgical suture is the main complication of laparoscopic sleeve gastrectomy (LSG) and is amenable to endoscopic therapy. The aim of this study was to evaluate the efficacy of a specifically designed self-expandable metal stent (SEMS) to seal the leakage. Patients and methods Over a 2-year period, patients referred for the treatment of post-LSG fistulas underwent placement of a fully covered esophagogastric SEMS with a specific design. Results A total of 10 patients were treated after a mean time of 50.9 days from the diagnosis of post-LSG leakage. A total of 11 SEMSs were placed. After stent removal, the leakage was seen to have healed in eight patients. Two patients who were treated with an SEMS with different mesh design, experienced stent migration, which required alternative endoscopic treatment such as the insertion of double-pigtail stents. After a mean follow-up period of 13.4 months, all patients were asymptomatic. Conclusions: Placement of a specifically designed SEMS for the treatment of post-LSG fistulas seems a promising first-line therapy according to this small series. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2016        PMID: 27706525     DOI: 10.1055/s-0042-117235

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  4 in total

1.  Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications.

Authors:  Ana Ponte; Rolando Pinho; Luísa Proença; Joana Silva; Jaime Rodrigues; Mafalda Sousa; João Carlos Silva; João Carvalho
Journal:  World J Gastrointest Endosc       Date:  2017-06-16

2.  Endoscopic management of leaks and fistulas after bariatric surgery: a systematic review and meta-analysis.

Authors:  Pawel Rogalski; Agnieszka Swidnicka-Siergiejko; Justyna Wasielica-Berger; Damian Zienkiewicz; Barbara Wieckowska; Eugeniusz Wroblewski; Andrzej Baniukiewicz; Magdalena Rogalska-Plonska; Grzegorz Siergiejko; Andrzej Dabrowski; Jaroslaw Daniluk
Journal:  Surg Endosc       Date:  2020-02-27       Impact factor: 4.584

3.  Customized bariatric stents for sleeve gastrectomy leak: are they superior to conventional esophageal stents? A systematic review and proportion meta-analysis.

Authors:  Hytham K S Hamid; Sameh H Emile; Alan A Saber; Mürşit Dincer; Diogo T H de Moura; Lennard P L Gilissen; Majid A Almadi; Mauro Montuori; Michel Vix; Luis G S Perisse; Nicolás Quezada; Fabio Garofalo; Radu Pescarus
Journal:  Surg Endosc       Date:  2020-11-06       Impact factor: 4.584

4.  A novel fully covered double-bump stent for staple line leaks after bariatric surgery: a retrospective analysis.

Authors:  Thomas C C Boerlage; Gerardus P M Houben; Marcel J M Groenen; Klaas van der Linde; Arnold W J M van de Laar; Marloes Emous; Paul Fockens; Rogier P Voermans
Journal:  Surg Endosc       Date:  2018-01-17       Impact factor: 4.584

  4 in total