Comparison of distal radius fracture intra-articular step reduction with volar locking plates and K wires: a retrospective review of quality and maintenance of fracture reduction.

N A Johnson1, J J Dias1, C J Wildin1, L Cutler1, B Bhowal1, A S Ullah1.   

Abstract

This study investigated the accuracy and maintenance of reduction of intra-articular steps achieved with closed reduction and percutaneous K wires and open reduction and a volar locking plate for the treatment of intra-articular distal radius fractures. We performed a retrospective review of 359 patients with an intra-articular fracture of their distal radius. Multivariate linear regression was undertaken to investigate the influence of multiple variables such as age, gender, initial displacement and treatment method on reduction despite differences between groups. A total of 36% of patients treated with K wires and 29% with volar locking plate had a step greater than or equal to 1 mm present on the first post-operative radiograph. A total of 23% treated with K wires and 28% with volar locking plate had a residual step of 1 mm or more on the last available radiograph. There was no difference identified between the two techniques for quality of initial reduction or persisting step on the last available radiographs. Step behaviour and further reduction of step post-operatively was similar for both treatment methods. Initial displacement and increased age influenced initial reduction. Initial fracture displacement shown radiologically was the only variable identified that influenced the persistence of a step on post-operative radiographs. LEVEL OF EVIDENCE: IV.

Entities:  

Keywords:  Distal radius fracture; Kirschner wires; volar locking plate; wrist fracture

Mesh:

Year:  2016        PMID: 27697898     DOI: 10.1177/1753193416669502

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  2 in total

1.  Relationship between plate removal and Soong grading following surgery for fractured distal radius.

Authors:  Caroline A Selles; Sam T H Reerds; Gert Roukema; Kees H van der Vlies; Berry I Cleffken; Niels W L Schep
Journal:  J Hand Surg Eur Vol       Date:  2017-08-21

2.  Juxta-articular Plate Fixation in Distal Radius Intra-articular Fractures with Accompanying Volar Free Fragments beyond the Watershed Line.

Authors:  Jun-Ku Lee; Soo-Hyun Lee; Young-Suk Sim; Tae-Ho Kim; Eugene Baek; Soo-Hong Han
Journal:  Clin Orthop Surg       Date:  2018-05-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.