Literature DB >> 27693171

The dosimetric impact of air in vaginal vault brachytherapy.

Áine Maxwell1, Niluja Thiruthaneeswaran1, Gerry Lowe1, Rachel Wills1, Samadara Sripali1, Peter J Hoskin2.   

Abstract

PURPOSE: Vaginal vault brachytherapy is an adjuvant treatment to reduce risk of local recurrence in endometrial cancer. Axial imaging has demonstrated the presence of air gaps between the surface of a cylindrical applicator and mucosal wall. The impact of these on dosimetry and applicability of the TG-43 formalism in the presence of air has been assessed. METHODS AND MATERIALS: The planning CT scans for a retrospective sample of 82 patients were examined for the presence of air gaps. These were quantified in terms of the radial and longitudinal aspect with reference to the applicator, frequency per patient, and location along the applicator. Monte Carlo calculations and ionization chamber measurements were made in a phantom to estimate the uncertainty of the TG-43 algorithm.
RESULTS: The overall incidence of air gaps was 91.4%. The most common radial size was between 2 and 3 mm (43.0%) that resulted in an average dose reduction of 14.8%. There is a strong correlation between radial dimension and TG-43 calculated dose reduction. Monte Carlo simulations and phantom measurements indicated that the inhomogeneity resulted in a maximum of 2.4% deviation from doses calculated using TG-43.
CONCLUSIONS: Air gaps are common. TG-43 formalism is not significantly compromised by the presence of air. However, the presence of the air does produce a displacement of the mucosal surface away from the applicator and this causes a significant dose reduction. Copyright Â
© 2016 American Brachytherapy Society. All rights reserved.

Entities:  

Keywords:  Brachytherapy; Endometrial cancer; TG-43; Vaginal vault

Mesh:

Year:  2016        PMID: 27693171     DOI: 10.1016/j.brachy.2016.08.006

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  2 in total

Review 1.  Vaginal cuff brachytherapy in endometrial cancer - a technically easy treatment?

Authors:  Sebastià Sabater; Ignacio Andres; Veronica Lopez-Honrubia; Roberto Berenguer; Marimar Sevillano; Esther Jimenez-Jimenez; Angeles Rovirosa; Meritxell Arenas
Journal:  Cancer Manag Res       Date:  2017-08-09       Impact factor: 3.989

2.  Experimental verification of Advanced Collapsed-cone Engine for use with a multichannel vaginal cylinder applicator.

Authors:  Brie Cawston-Grant; Hali Morrison; Geetha Menon; Ron S Sloboda
Journal:  J Appl Clin Med Phys       Date:  2017-03-20       Impact factor: 2.102

  2 in total