Literature DB >> 27692754

Validation of Bayesian analysis of compartmental kinetic models in medical imaging.

Arkadiusz Sitek1, Quanzheng Li2, Georges El Fakhri2, Nathaniel M Alpert2.   

Abstract

INTRODUCTION: Kinetic compartmental analysis is frequently used to compute physiologically relevant quantitative values from time series of images. In this paper, a new approach based on Bayesian analysis to obtain information about these parameters is presented and validated.
MATERIALS AND METHODS: The closed-form of the posterior distribution of kinetic parameters is derived with a hierarchical prior to model the standard deviation of normally distributed noise. Markov chain Monte Carlo methods are used for numerical estimation of the posterior distribution. Computer simulations of the kinetics of F18-fluorodeoxyglucose (FDG) are used to demonstrate drawing statistical inferences about kinetic parameters and to validate the theory and implementation. Additionally, point estimates of kinetic parameters and covariance of those estimates are determined using the classical non-linear least squares approach. RESULTS AND DISCUSSION: Posteriors obtained using methods proposed in this work are accurate as no significant deviation from the expected shape of the posterior was found (one-sided P>0.08). It is demonstrated that the results obtained by the standard non-linear least-square methods fail to provide accurate estimation of uncertainty for the same data set (P<0.0001).
CONCLUSIONS: The results of this work validate new methods for a computer simulations of FDG kinetics. Results show that in situations where the classical approach fails in accurate estimation of uncertainty, Bayesian estimation provides an accurate information about the uncertainties in the parameters. Although a particular example of FDG kinetics was used in the paper, the methods can be extended for different pharmaceuticals and imaging modalities.
Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bayesian inference; Dynamic nuclear imaging; Kinetic analysis

Mesh:

Substances:

Year:  2016        PMID: 27692754      PMCID: PMC5720163          DOI: 10.1016/j.ejmp.2016.09.010

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  10 in total

1.  Positron emission tomography compartmental models: a basis pursuit strategy for kinetic modeling.

Authors:  Roger N Gunn; Steve R Gunn; Federico E Turkheimer; John A D Aston; Vincent J Cunningham
Journal:  J Cereb Blood Flow Metab       Date:  2002-12       Impact factor: 6.200

2.  Estimation and inference in pharmacokinetic models: the effectiveness of model reformulation and resampling methods for functions of parameters.

Authors:  D Niedzwiecki; J S Simonoff
Journal:  J Pharmacokinet Biopharm       Date:  1990-08

3.  Limitations of Poisson statistics in describing radioactive decay.

Authors:  Arkadiusz Sitek; Anna M Celler
Journal:  Phys Med       Date:  2015-10-23       Impact factor: 2.685

4.  Analysis of nonlinear regression models: a cautionary note.

Authors:  Shyamal D Peddada; Joseph K Haseman
Journal:  Dose Response       Date:  2006-05-01       Impact factor: 2.658

5.  The Monte Carlo method.

Authors:  N METROPOLIS; S ULAM
Journal:  J Am Stat Assoc       Date:  1949-09       Impact factor: 5.033

6.  The [14C]deoxyglucose method for the measurement of local cerebral glucose utilization: theory, procedure, and normal values in the conscious and anesthetized albino rat.

Authors:  L Sokoloff; M Reivich; C Kennedy; M H Des Rosiers; C S Patlak; K D Pettigrew; O Sakurada; M Shinohara
Journal:  J Neurochem       Date:  1977-05       Impact factor: 5.372

7.  Bayesian Analysis of a One Compartment Kinetic Model Used in Medical Imaging.

Authors:  Peter Malave; Arkadiusz Sitek
Journal:  J Appl Stat       Date:  2015       Impact factor: 1.404

8.  (18)F-Deoxyglucose (FDG) kinetics evaluated by a non-compartment model based on a linear regression function using a computer based simulation: correlation with the parameters of the two-tissue compartment model.

Authors:  Ludwig G Strauss; Leyun Pan; Caixia Cheng; Antonia Dimitrakopoulou-Strauss
Journal:  Am J Nucl Med Mol Imaging       Date:  2012-10-15

9.  Noninvasive determination of local cerebral metabolic rate of glucose in man.

Authors:  S C Huang; M E Phelps; E J Hoffman; K Sideris; C J Selin; D E Kuhl
Journal:  Am J Physiol       Date:  1980-01

10.  Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography.

Authors:  D Feng; S C Huang; X Wang
Journal:  Int J Biomed Comput       Date:  1993-03
  10 in total
  1 in total

1.  Efficient DCE-MRI Parameter and Uncertainty Estimation Using a Neural Network.

Authors:  Yannick Bliesener; Jay Acharya; Krishna S Nayak
Journal:  IEEE Trans Med Imaging       Date:  2019-11-26       Impact factor: 10.048

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.