Literature DB >> 27692578

Patient-centered and clinical outcomes of mandibular overdentures retained with the locator system: A prospective observational study.

Lucia Fernandez-Estevan1, Javier Montero2, Eduardo J Selva Otaolaurruchi3, Fernanda Sola Ruiz3.   

Abstract

STATEMENT OF PROBLEM: Whether clinical or demographic variables affect the perception of treatment in terms of quality of life and satisfaction is unknown.
PURPOSE: The purpose of this prospective study was to make an evidence-based assessment of the treatment outcomes (patient- and clinically based) of locator-retained mandibular overdentures.
MATERIAL AND METHODS: This prospective observational study assessed patients with edentulism who had worn mandibular overdentures supported by 2 implants and retained by the locator system for at least 1 year of functional life (N=80). Medical histories were reviewed, and patients underwent oral examinations. Prosthetic clinical outcomes and patient well-being were registered using the Oral Health Impact Profile 20 (OHIP-20) and Oral Satisfaction Scale (OSS).
RESULTS: Patient well-being scored an overall OHIP-20 score of 19.0 ±14.0 of 80 (the higher the score, the greater the impact and the worse the oral health-related quality of life); overall oral satisfaction was 8.3 ±1.7 of 10. Women suffered greater social impact (0.8 ±1.0) and disability (0.4 ±0.8) than men (0.4 ±0.7 versus 0.2 ±0.4, respectively). Impact on well-being was inversely proportional to both patient age and the age of the prosthesis (r=-0.25; P<.01). Implants had been placed on average 73.6 ±39.2 months previously, showing a survival rate of 82.5%. Most of the overdentures had been functioning for over 60 months. Relining (46.3%), readjustments (82.5%), and changes of nylon retention (1.5 ±1.8 per patient over 60 months of use) devices negatively influenced well-being.
CONCLUSIONS: Mandibular overdentures produced good results with regard to quality of life and oral satisfaction, but attention should be paid to factors affecting clinical outcomes and patient well-being.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27692578     DOI: 10.1016/j.prosdent.2016.07.013

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures.

Authors:  Nesreen El Mekawy; Mohamed-Yosry Elhawary
Journal:  J Clin Exp Dent       Date:  2019-01-01

2.  Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study.

Authors:  Ursina Nagy; Christophe Guédat; Catherine Giannopoulou; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2019-07-18

3.  Clinical performance of LOCATOR® attachments: A retrospective study with 1-8 years of follow-up.

Authors:  Christophe Guédat; Ursina Nagy; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2018-07-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.