Literature DB >> 27689558

Recommendations for measuring non-image-forming effects of light: A practical method to apply on cognitive impaired and unaffected participants.

J van Duijnhoven1,2, M P J Aarts1,2, M B C Aries1,3, M N Böhmer4,5, A L P Rosemann1,2.   

Abstract

BACKGROUND: The non-image-forming effects of luminous radiation on people with intellectual disabilities or dementia received attention from researchers. Such studies, however, have generally been conducted using disparate methodologies which precludes generalization and reproducibility.
OBJECTIVE: The aim of this study was to determine the practical applicability of measurement devices for studies investigating non-image-forming effects of luminous radiation, specifically for people with intellectual disabilities or dementia.
METHODS: In three experiments, ten cognitive impaired people and thirty-nine unaffected subjects participated by wearing one or more portable devices. Six devices were assessed in total. Measurement data was accompanied with user experiences obtained from questionnaires, interviews and observations in order to assess the devices on practical and comfort issues.
RESULTS: On average, the devices worn by the cognitive impaired subjects were not experienced as annoying or irritating. No significant differences are found between genders and for one of the portable devices significantly less annoyance was reported by the cognitive impaired participants compared to the unaffected group of participants. INNOVATIVE SOLUTION: The three phases of the research process in towards measuring personal luminous exposures are: selection of the most suitable portable device, application of the assessment method, and the application of the device in the (pilot) study.
CONCLUSIONS: However, the findings of this study suggest that inaccuracies potentially caused by practical and comfort issues associated with the portable devices need to be considered.

Entities:  

Keywords:  NIF; cognition, wearables; dementia; intellectual disability; light measurements; non-visual effects

Mesh:

Year:  2017        PMID: 27689558     DOI: 10.3233/THC-161258

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  3 in total

1.  The importance of including position and viewing direction when measuring and assessing the lighting conditions of office workers.

Authors:  J van Duijnhoven; M P J Aarts; H S M Kort
Journal:  Work       Date:  2019

2.  Shedding light on light exposure in elderly with intellectual disabilities.

Authors:  M N Böhmer; M J Valstar; M P J Aarts; P J E Bindels; A Oppewal; E J W van Someren; D A M Festen
Journal:  J Intellect Disabil Res       Date:  2021-02-16

3.  Light up: an intervention study of the effect of environmental dynamic lighting on sleep-wake rhythm, mood and behaviour in older adults with intellectual disabilities.

Authors:  M N Böhmer; A Oppewal; M J Valstar; P J E Bindels; E J W van Someren; D A M Maes-Festen
Journal:  J Intellect Disabil Res       Date:  2022-08-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.