Literature DB >> 2768918

[Clinical assessment of prosthetic valve replacement of the right-sided cardiac valves: mechanical or bioprosthesis?].

M Masuda, Y Kawachi, M Oe, R Tominaga, K Kinoshita, A Nakashima, T Asou, Y Toshima, J Tanaka, K Tokunaga.   

Abstract

Clinical results with mechanical and bioprosthetic valve replacements for tricuspid and/or pulmonary positions were reviewed. Between February 1975 and December 1985, 34 bioprostheses (B) (22 Hancock, 9 Ionescu-Shiley and 3 Carpentier-Edwards pericardial) and 18 mechanical prostheses (M) (St. Jude Medical) were implanted in our institute excluding hospital death. Group with B included 29 tricuspid valve replacements and 5 pulmonary valve replacements. Group with M included 9 tricuspid valve replacements, 7 pulmonary valve replacements and 1 both valve replacements. The cumulative follow-up period was 207.2 patient-years (p-t) in group B and 55.0 p-y in group M. The incidence of valve failure was 0.48 +/- 0.48% per p-y in group B and 7.27 +/- 3.64% per p-y in group M (p less than 0.001). The incidence of valve-related events was 1.93 +/- 0.97% per p-y in group B and 9.09 +/- 4.07% per p-y in group M (p less than 0.001). At 3 years, the percent free of valve failure was 100 +/- 0% in group B and 76.8 +/- 10.2% in group M (p less than 0.05). Fourteen bioprosthetic valves (B') and 10 mechanical valves (M') were implanted at the right-sided cardiac valve position alone. The cumulative follow-up period was 94.2 p-y in group B' and 32.3 p-y in group M'. The incidence of valve-related events was 1.06 +/- 1.06% per p-y in group B' and 12.4 +/- 6.19% per p-y in group M' (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2768918

Source DB:  PubMed          Journal:  Nihon Kyobu Geka Gakkai Zasshi        ISSN: 0369-4739


  3 in total

1.  Isolated pulmonary valve replacement: analysis of 27 years of experience.

Authors:  Shigehiko Tokunaga; Munetaka Masuda; Akira Shiose; Yukihiro Tomita; Shigeki Morita; Ryuji Tominaga
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

2.  Tricuspid valve replacement with the St. Jude Medical valve.

Authors:  S Aoyagi; Y Nishi; T Kawara; A Oryoji; H Hara; K Kosuga; K Ohishi
Journal:  Surg Today       Date:  1994       Impact factor: 2.549

3.  Silicon amendment induces synergistic plant defense mechanism against pink stem borer (Sesamia inferens Walker.) in finger millet (Eleusine coracana Gaertn.).

Authors:  Kundansing Rajpalsing Jadhao; Anuradha Bansal; Gyana R Rout
Journal:  Sci Rep       Date:  2020-03-06       Impact factor: 4.379