Literature DB >> 27689143

Accuracy of Contrast-Enhanced Ultrasound in the Diagnosis of Bile Duct Obstruction.

F J P Fontán1, Á R Reboredo2, A R Siso1.   

Abstract

PURPOSE: To investigate the ability of contrast-enhanced ultrasound (CEUS) to differentiate benign from malignant lesions causing biliary duct obstruction.
MATERIALS AND METHODS: Between November 2006 and December 2013, 59 patients with bile duct obstruction of undetermined cause in baseline ultrasound underwent CEUS study. The enhancement and posterior washout were analyzed in real time all along the study duration (5'). The final diagnosis suggested by CEUS was compared with histologic diagnosis (47.5%) or with radiologic follow-up with TC, RM or ERCP.
RESULTS: Final diagnoses included 42 malignant lesions (cholangiocarcinoma n=22, metastases n=6, pancreatic carcinoma n=6, hepatocarcinoma n=4, gallbladder carcinoma n=2, ampullary carcinoma n=1 and lymphoma n=1) and 17 benign lesions (lithiasis or biliary sludge n=15, xanthogranulomatous cholecystitis n=1 and indeterminate n=1). CEUS accuracy compared with final diagnoses based on combined reference standard was 86.4%. CEUS correctly identified 36 of 42 malignant lesions (sensibility 85.7%) and 15 of 17 benign lesions (specificity 88.2%). The positive predictive value of CEUS for malignancy was 94.7%, while the negative predictive value was 71.4%.
CONCLUSION: CEUS is useful to differentiate between benign and malignant causes of obstructive jaundice. This technique improves the detection of bile duct invasion in hepatic neoplasms and permits better evaluation of intra- and extraductal extension of hilar hepatobiliary tumors.

Entities:  

Keywords:  abdomen; biliary system; ultrasound

Year:  2015        PMID: 27689143      PMCID: PMC5023202          DOI: 10.1055/s-0035-1555880

Source DB:  PubMed          Journal:  Ultrasound Int Open        ISSN: 2199-7152


  14 in total

Review 1.  Microbubble-enhanced US in body imaging: what role?

Authors:  Stephanie R Wilson; Peter N Burns
Journal:  Radiology       Date:  2010-10       Impact factor: 11.105

2.  The safety of Sonovue in abdominal applications: retrospective analysis of 23188 investigations.

Authors:  Fabio Piscaglia; Luigi Bolondi
Journal:  Ultrasound Med Biol       Date:  2006-09       Impact factor: 2.998

3.  The EFSUMB Guidelines and Recommendations on the Clinical Practice of Contrast Enhanced Ultrasound (CEUS): update 2011 on non-hepatic applications.

Authors:  F Piscaglia; C Nolsøe; C F Dietrich; D O Cosgrove; O H Gilja; M Bachmann Nielsen; T Albrecht; L Barozzi; M Bertolotto; O Catalano; M Claudon; D A Clevert; J M Correas; M D'Onofrio; F M Drudi; J Eyding; M Giovannini; M Hocke; A Ignee; E M Jung; A S Klauser; N Lassau; E Leen; G Mathis; A Saftoiu; G Seidel; P S Sidhu; G ter Haar; D Timmerman; H P Weskott
Journal:  Ultraschall Med       Date:  2011-08-26       Impact factor: 6.548

Review 4.  Role of contrast enhanced ultrasound in the assessment of biliary duct disease.

Authors:  Zeno Spârchez; Pompilia Radu
Journal:  Med Ultrason       Date:  2014-03       Impact factor: 1.611

Review 5.  The role of imaging methods in identifying the causes of extrahepatic cholestasis.

Authors:  Ion Rogoveanu; Dan Ionut Gheonea; Adrian Saftoiu; Tudorel Ciurea
Journal:  J Gastrointestin Liver Dis       Date:  2006-09       Impact factor: 2.008

6.  Ultrasound Findings of Intraductal Papillary Neoplasm in Bile Duct and the Added Value of Contrast-Enhanced Ultrasound.

Authors:  L N Liu; H X Xu; S G Zheng; L P Sun; L H Guo; Y F Zhang; J M Xu; C Liu; X H Xu
Journal:  Ultraschall Med       Date:  2014-09-04       Impact factor: 6.548

7.  Contrast-enhanced ultrasound in the biliary system: Potential uses and indications.

Authors:  Hui-Xiong Xu
Journal:  World J Radiol       Date:  2009-12-31

Review 8.  Evaluation of gallbladder and biliary duct disease using microbubble contrast-enhanced ultrasound.

Authors:  L M Meacock; M E Sellars; P S Sidhu
Journal:  Br J Radiol       Date:  2010-07       Impact factor: 3.039

Review 9.  The sensitivity and role of ultrasound in the evaluation of biliary obstruction.

Authors:  L H Blackbourne; R C Earnhardt; C L Sistrom; P Abbitt; R S Jones
Journal:  Am Surg       Date:  1994-09       Impact factor: 0.688

10.  Enhancement pattern of hilar cholangiocarcinoma: contrast-enhanced ultrasound versus contrast-enhanced computed tomography.

Authors:  Hui-Xiong Xu; Li-Da Chen; Xiao-Yan Xie; Xiao-Hua Xie; Zuo-Feng Xu; Guang-Jian Liu; Man-Xia Lin; Zhu Wang; Ming-De Lu
Journal:  Eur J Radiol       Date:  2009-05-22       Impact factor: 3.528

View more
  1 in total

1.  Spatial analysis of hepatobiliary abnormalities in a population at high-risk of cholangiocarcinoma in Thailand.

Authors:  Kavin Thinkhamrop; Apiporn T Suwannatrai; Nittaya Chamadol; Narong Khuntikeo; Bandit Thinkhamrop; Pongdech Sarakarn; Darren J Gray; Kinley Wangdi; Archie C A Clements; Matthew Kelly
Journal:  Sci Rep       Date:  2020-10-08       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.