Literature DB >> 27686711

Dynamic ECG features for atrial fibrillation recognition.

Nurul Ashikin Abdul-Kadir1, Norlaili Mat Safri2, Mohd Afzan Othman1.   

Abstract

BACKGROUND: Atrial fibrillation (AF) can cause the formation of blood clots in the heart. The clots may move to the brain and cause a stroke. Therefore, this study analyzed the ECG features of AF and normal sinus rhythm signals for AF recognition which were extracted by using a second-order dynamic system (SODS) concept.
OBJECTIVE: To find the appropriate windowing length for feature extraction based on SODS and to determine a machine learning method that could provide higher accuracy in recognizing AF.
METHOD: ECG features were extracted based on a dynamic system (DS) that uses a second-order differential equation to describe the short-term behavior of ECG signals according to the natural frequency (ω), damping coefficient, (ξ), and forcing input (u). The extracted features were windowed into 2, 3, 4, 6, 8, and 10 second episodes to find the appropriate windowing size for AF signal processing. ANOVA and t-tests were used to determine the significant features. In addition, pattern recognition machine learning methods (an artificial neural network (ANN) and a support vector machine (SVM)) with k-fold cross validation (k-CV) were used to develop the ECG recognition system.
RESULTS: Significant differences (p < 0.0001) were observed among all ECG groups (NSR, N, AF) using 2, 3, 4 and 6 second episodes for the features ω and u/ω; 4, 6 and 8 second episodes for features ω and u; 4 and 6 second episodes for features ω, u and u/ω, and; 10 second episodes for the feature ξ. The highest accuracy for AF recognition (AF, NSR) using ANN with k-CV was 95.3% using combination of features (ω and u; ω, u and u/ω) and SVM with k-CV was 95.0% using a combination of features ω, u and u/ω.
CONCLUSION: This study found that 4 s is the most appropriate windowing length, using two features (ω and u) for AF detection with an accuracy of 95.3%. Moreover, the pattern recognition learning machine uses an ANN with 10-fold cross validation based on DS.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Artificial neural network; Atrial fibrillation; Dynamic system; Pattern recognition; Support vector machine; k-fold cross validation

Mesh:

Year:  2016        PMID: 27686711     DOI: 10.1016/j.cmpb.2016.08.021

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  3 in total

1.  Arrhythmia Evaluation in Wearable ECG Devices.

Authors:  Muammar Sadrawi; Chien-Hung Lin; Yin-Tsong Lin; Yita Hsieh; Chia-Chun Kuo; Jen Chien Chien; Koichi Haraikawa; Maysam F Abbod; Jiann-Shing Shieh
Journal:  Sensors (Basel)       Date:  2017-10-25       Impact factor: 3.576

Review 2.  A Review of Atrial Fibrillation Detection Methods as a Service.

Authors:  Oliver Faust; Edward J Ciaccio; U Rajendra Acharya
Journal:  Int J Environ Res Public Health       Date:  2020-04-29       Impact factor: 3.390

Review 3.  How machine learning is impacting research in atrial fibrillation: implications for risk prediction and future management.

Authors:  Ivan Olier; Sandra Ortega-Martorell; Mark Pieroni; Gregory Y H Lip
Journal:  Cardiovasc Res       Date:  2021-06-16       Impact factor: 10.787

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.