Letter to the Editor: Measured Values Incompatible with Human Life.

Eduard Clot-Silla1, Ana Argudo-Ramirez1, Xavier Fuentes-Arderiu1.   

Abstract

Entities:  

Year:  2011        PMID: 27683391      PMCID: PMC4975288     

Source DB:  PubMed          Journal:  EJIFCC        ISSN: 1650-3414


× No keyword cloud information.

INTRODUCTION

To the Editor, In the last decades, systems for quality control and improvement of measured values have been widely developed and implemented in the clinical laboratory. Thus, errors of any kind committed in clinical laboratories at any stage of the measurement process have declined substantially (1). There are evidences that in the clinical laboratory these errors mainly occur at the pre-analytical and post-analytical steps of the total analytical process (1). The adoption of standards of quality such as ISO 9001:2008(2) or, better, ISO 15189:2007(3) — a specific document on technical competence in clinical laboratories — are actually cornerstones for trying to reach the excellence in the practice of clinical laboratory sciences. This excellence is directly translated into an improvement of the clinical laboratory information provided to the clinician and, consequently, an improvement of the clinical decision making process. However, sometimes we can find clinical laboratory information in which although all steps of the analytical process have been exhaustively controlled, the information seems to be not reliable. This could be the case when a very extreme biological quantity value is found in a patient. Accordingly, it might be of interest, from a clinical laboratory point of view, to know those measured values which, being extremely high or low ones, have been obtained in the absence of performance abnormalities of the measuring system and would indicate that an error has occurred at any phase of the measurement process. Such an extreme measured value must be reviewed by professionals of clinical laboratory. But, what would it mean when an apparently impossible measured value has been found, and there is no evidence of error at any phase of the measurement process? A measured value from a patient alive is really clinically impossible when it is not compatible with human life. Thus, when focusing on these apparently impossible values, the idea ‘measured values incompatible with human life’ easily arise in our mind. Unfortunately, for most biological quantities the information available on this topic is extremely rare and, consequently, it is very difficult to find publications regarding this issue. Moreover, in the few references found, the studies do not explain the experimental design, it is not detailed enough to assure its reliability. In Table 1 there are few examples of publications on this kind of values (4-6) Despite the importance of these works, their results must be taken into account with caution; in Table 1, we can see an example. In the work of Vogt and Oesterle (4) a concentration of sodium ion in plasma lower than 100 mmol/L is considered incompatible with human life. Is this incompatibility verifiable? Hardly. Firstly, we will never be able to reproduce the exact conditions in which was found this measured value and, secondly, some publication can be found refusing this measured value as incompatible with human life. In a recent publication, concentration of sodium ion in plasma in a schizophrenic potomaniac patient was only 95 mmol/L (7). This patient was alive with this concentration of sodium ion in plasma and survived after electrolyte administration. There are only conclusive evidences of measured values incompatible with human life when the studies deal with absolute deficiency of essential components for human life, such as homozygous antithrombin deficiencies (8), for example. In the other hand, in toxicology, several concepts related to measured values incompatible with life in non-human populations have been defined: absolute lethal concentration (LC100), median lethal concentration (LC50) and minimum lethal concentration (LCmin) (9). However, for obvious reasons, this kind of concepts must not be applied to humans.
Table 1.

Published values incompatible with human life for some biological quantities.

Quantity1Values incompatible with human liveReference
P—Chloride; subst.c.<65 and > 138 mmol/L4
P—Ethanol; subst.c.>97.6 mmol/L5
Pt—Plasma; pH< 6.8 and >7.86
P—Potassium ion; subst.c.< 1.3 and >9.0 mmol/L4
P—Sodium ion; subst.c.< 100 and >191 mmol/L4

1 Quantities are described according to IFCC and IUPAC recommendations (13); “P” means blood plasma, “Pt” means patient, and “subst.c.” means substance concentration.

It could be of interest to set a discriminant value to decide when a measured values is non attributable to an alive human, but it is not an easy issue. Firstly, it is well known the amazing adaptability of humans to external and stress situations, as seen in studies dealing with physiological adaptation to extreme stress situations, as low oxygen partial pressure in extreme altitudes (10). Secondly, worldwide metrological harmonization has only been achieved for the measurement of very few biological quantities, so the measured values presumptively incompatible with human life obtained by one laboratory could not be verified by other laboratories. And, thirdly, and maybe the most important, serious ethical dilemmas arise in designing specific models to verify the most extreme measured value of any biological property that could be assumed as compatible with human life. Thus, a deep sight into this topic provides the conclusion that, for any biological quantity, it is not possible to set a limit which clearly define a distinction between measured values compatible or non compatible with human life due to the intrinsic ethical and methodological limitations. Probably, an unlikelyhood limit is the best surrogate for a value incompatible with human life. An ‘unlikelyhood limit’ is defined as a «measured value with a very low probability of belonging to a patient» (11). This way, it can be set, using statistical tools, an interval of measured values, which limits are defined by fractiles that exclude a defined fraction of laboratory measured values obtained and validated during a defined period of time (12). All about measured values incompatible with human life is interesting in biological anthropology, health care sciences, in general, and clinical laboratory sciences, in particular. However, it is a complex issue, and some questions arise from the ambiguity and complexity of this topic regarding the feasibility of their use. Will it be possible, in a future, to create an international databank of these kind of values? Could it be possible to compare these measured values between laboratories? Could these measured values be incompatible with human life applicable to all patients or should they be stratified by gender, age or ethnics? Are unlikelyhood limits as near as we can be of the values incompatible with human life?
  6 in total

1.  Evaluating sodium bicarbonate controversy.

Authors:  V Rosival
Journal:  Chest       Date:  2001-05       Impact factor: 9.410

2.  Reportable interval of patient examination results and ISO 15189.

Authors:  Iván Suárez-Vega; Xavier Fuentes-Arderiu
Journal:  Clin Chem Lab Med       Date:  2005       Impact factor: 3.694

3.  Caudwell xtreme Everest expedition.

Authors:  Michael P W Grocott; Daniel S Martin; Mark H Wilson; Kay Mitchell; Sundeep Dhillon; Monty G Mythen; Hugh E Montgomery; Denny Z H Levett
Journal:  High Alt Med Biol       Date:  2010       Impact factor: 1.981

Review 4.  The detection and prevention of errors in laboratory medicine.

Authors:  Mario Plebani
Journal:  Ann Clin Biochem       Date:  2009-12-01       Impact factor: 2.057

5.  [Severe and acute hyponatremia in a schizophrenic patient with potomania].

Authors:  M D Macías Robles; M P López Fonticiella; M Maciá Bobés; A Fernández San Martín
Journal:  An Sist Sanit Navar       Date:  2009 Jan-Apr       Impact factor: 0.829

6.  [Extreme results in electrolyte determination].

Authors:  W Vogt; B Oesterle
Journal:  Wien Klin Wochenschr Suppl       Date:  1992
  6 in total
  1 in total

1.  Machine Learning Prediction of Hypoglycemia and Hyperglycemia From Electronic Health Records: Algorithm Development and Validation.

Authors:  Alexander Benedikt Leichtle; Harald Witte; Christos Nakas; Lia Bally
Journal:  JMIR Form Res       Date:  2022-07-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.