Literature DB >> 27683194

Comparison of early osseointegration of SLA® and SLActive® implants in maxillary sinus augmentation: a pilot study.

Jamil Alayan1, Cedryck Vaquette2, Siamak Saifzadeh2, Dietmar Hutmacher2, Saso Ivanovski1.   

Abstract

OBJECTIVE: To assess the impact of a hydrophilic implant surface (SLActive® ) placed into augmented maxillary sinuses on bone-to-implant contact (BIC) and surrounding tissue composition when compared to a hydrophobic surface (SLA® ).
MATERIAL AND METHODS: Four sheep underwent bilateral sinus augmentation. Each sinus received anorganic bovine bone mineral + autogenous bone (ABBM + AB). Sixteen implants were subsequently placed 12 weeks postgrafting with each sinus receiving a control (SLA® ) and test implant (SLActive® ). Two animals were sacrificed at 2 weeks and another two animals were sacrificed at 4 weeks postimplantation. The eight sinuses and 16 implants were processed for histomorphometry, which assessed bone-to-implant contact (%BIC) and tissue elements (woven bone - WB, lamellar bone - LB, soft tissue - ST) in the interthread region of implants within the augmented sinus.
RESULTS: There was a statistically significant increase in %BIC at week 4 compared to the week 2 animals in both test (P < 0.005) and control (P < 0.005) groups. There was a statistically significant greater %BIC around test implants when compared to control implants in both week 2 (P < 0.05) and week 4 animals (P < 0.05). Greater %WB (11.17% ±6.82) and %LB (11.06% ±3.67) were seen in the test implants when compared to the control implants independent of time. This was only statistically significant for %LB (P < 0.05). A statistically significant reduction of 16.78% (±6.19) in %ST was noted in test implants when compared to control implants (P < 0.05) independent of time.
CONCLUSION: Both time and the use of hydrophilic implant surface had a positive impact on %BIC around implants placed into augmented maxillary sinuses. Hydrophilic implant surfaces also had a positive impact on surrounding tissue composition. Larger trials are needed to better assess and detect differences between these two surfaces in augmented maxillary sinuses.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  animal model; bone grafting; bone regeneration; bone substitute; dental implant; histomorphometry; maxillary sinus augmentation

Mesh:

Substances:

Year:  2016        PMID: 27683194     DOI: 10.1111/clr.12988

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

Review 1.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

2.  Development of a new critical size defect model in the paranasal sinus and first approach for defect reconstruction-An in vivo maxillary bone defect study in sheep.

Authors:  R Rothweiler; S Kuhn; T Stark; S Heinemann; A Hoess; M A Fuessinger; L S Brandenburg; R Roelz; M C Metzger; U Hubbe
Journal:  J Mater Sci Mater Med       Date:  2022-10-20       Impact factor: 4.727

3.  Is maxillary diastema an appropriate site for implantation in rats?

Authors:  Gang Yue; Husham Edani; Andrew Sullivan; Shuying Jiang; Hamed Kazerani; Mohammad Ali Saghiri
Journal:  Int J Implant Dent       Date:  2020-02-26

4.  Implant stability of narrow diameter implants in hyperglycemic patients-A 3-month case-control study.

Authors:  Daniel Diehl; Marianna Winkler; Hakan Bilhan; Anton Friedmann
Journal:  Clin Exp Dent Res       Date:  2022-05-16

5.  The osseointegration and stability of dental implants with different surface treatments in animal models: a network meta-analysis.

Authors:  Chun-Ping Hao; Nan-Jue Cao; Yu-He Zhu; Wei Wang
Journal:  Sci Rep       Date:  2021-07-05       Impact factor: 4.379

6.  Bone Response to Two Dental Implants with Different Sandblasted/Acid-Etched Implant Surfaces: A Histological and Histomorphometrical Study in Rabbits.

Authors:  Antonio Scarano; Adriano Piattelli; Alesandro Quaranta; Felice Lorusso
Journal:  Biomed Res Int       Date:  2017-12-27       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.