Electrical Impedance Tomography During Mechanical Ventilation.

Brian K Walsh1, Craig D Smallwood2.   

Abstract

Electrical impedance tomography (EIT) is a noninvasive, non-radiologic imaging modality that may be useful for the quantification of lung disorders and titration of mechanical ventilation. The principle of operation is based on changes in electrical conductivity that occur as a function of changes in lung volume during ventilation. EIT offers potentially important benefits over standard imaging modalities because the system is portable and non-radiologic and can be applied to patients for long periods of time. Rather than providing a technical dissection of the methods utilized to gather, compile, reconstruct, and display EIT images, the present article seeks to provide an overview of the clinical application of this technology as it relates to monitoring mechanical ventilation and providing decision support at the bedside. EIT has been shown to be useful in the detection of pneumothoraces, quantification of pulmonary edema and comparison of distribution of ventilation between different modes of ventilation and may offer superior individual titration of PEEP and other ventilator parameters compared with existing approaches. Although application of EIT is still primarily done within a research context, it may prove to be a useful bedside tool in the future. However, head-to-head comparisons with existing methods of mechanical ventilation titration in humans need to be conducted before its application in general ICUs can be recommended.
Copyright © 2016 by Daedalus Enterprises.

Entities:  

Keywords:  electrical impedance tomography; lung imaging; mechanical ventilation; regional distribution of ventilation

Mesh:

Year:  2016        PMID: 27682815     DOI: 10.4187/respcare.04914

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  6 in total

Review 1.  Electrical impedance tomography.

Authors:  Beatriz Lobo; Cecilia Hermosa; Ana Abella; Federico Gordo
Journal:  Ann Transl Med       Date:  2018-01

2.  An on-line processing strategy for head movement interferences removal of dynamic brain electrical impedance tomography based on wavelet decomposition.

Authors:  Ge Zhang; Weichen Li; Hang Ma; Xuechao Liu; Meng Dai; Canhua Xu; Haoting Li; Xiuzhen Dong; Xingwang Sun; Feng Fu
Journal:  Biomed Eng Online       Date:  2019-05-09       Impact factor: 2.819

3.  High PEEP Levels during CPR Improve Ventilation without Deleterious Haemodynamic Effects in Pigs.

Authors:  Miriam Renz; Leah Müllejans; Julian Riedel; Katja Mohnke; René Rissel; Alexander Ziebart; Bastian Duenges; Erik Kristoffer Hartmann; Robert Ruemmler
Journal:  J Clin Med       Date:  2022-08-22       Impact factor: 4.964

4.  Derecruitment volume assessment derived from pressure-impedance curves with electrical impedance tomography in experimental acute lung injury.

Authors:  Xiu-Mei Sun; Guang-Qiang Chen; Yu-Mei Wang; Yi-Min Zhou; Jing-Ran Chen; Kun-Ming Cheng; Yan-Lin Yang; Lin-Lin Zhang; Hong-Liang Li; Jian-Xin Zhou
Journal:  J Int Med Res       Date:  2020-08       Impact factor: 1.671

5.  Simple Wireless Impedance Pneumography System for Unobtrusive Sensing of Respiration.

Authors:  Pablo Aqueveque; Britam Gómez; Emyrna Monsalve; Enrique Germany; Paulina Ortega-Bastidas; Sebastián Dubo; Esteban J Pino
Journal:  Sensors (Basel)       Date:  2020-09-14       Impact factor: 3.576

6.  Effect of Electrical Impedance Tomography-Guided Early Mobilization in Patients After Major Upper Abdominal Surgery: Protocol for a Prospective Cohort Study.

Authors:  Xuan Song; Daqiang Yang; Maopeng Yang; Yahu Bai; Bingxin Qin; Shoucheng Tian; Gangbing Song; Xiuyan Guo; Ranran Dong; Yuanyuan Men; Ziwei Liu; Xinyan Liu; Chunting Wang
Journal:  Front Med (Lausanne)       Date:  2021-12-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.