Dynamic hip screw fixation of intertrochanteric fractures without using traction table.

S Kumar, G N Chadha.   

Abstract

To evaluate a new technique of Dynamic hip screw (DHS) fixation without using traction table. From july 2006 to july 2012, 328 patients undergoing DHS fixation using manual traction technique were evaluated in terms of Tip apex distance (TAD), -quality of fracture reduction, operation time, preoperative preparation time. In 97% cases good to moderate reduction could be achieved. The mean TAD was 19.2 millimeters, mean operation time 37 minutes and screw cutout rate was only 0.91%. This technique is easy, reproducible, cheap do not sacrifice reduction alignment, screw position and is extremely beneficial in polytrauma patients where multiple surgeries are to be done.

Entities:  

Mesh:

Year:  2016        PMID: 27682298

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  1 in total

1.  [A comparative study on effectiveness of closed reduction and internal fixation of intertrochanteric fracture assisted with skeletal tractor and traction table].

Authors:  Gangqiang Du; Zhigang Wang; Shuye Yang; Long Jia; Peng Li; Kai Zhang; Jianhao Jiang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-04-15