Literature DB >> 27681455

Management of pseudophakic myopic anisometropic amblyopia with piggyback Visian® implantable collamer lens.

Sherif A Eissa1.   

Abstract

PURPOSE: To assess the outcomes of sulcus implantation of the Visian® implantable collamer lens (ICL) to correct pseudophakic myopic anisometropic amblyopia with myopic shift and/or primary refractive overcorrection.
METHODS: Prospective case series enrolled 14 pseudophakic eyes of 14 patients, 5-9 years old, with history of cataract surgery and primary in the bag-intraocular lenses (IOL) implantation, followed by myopic shift and/or refractive overcorrection and anisometropic amblyopia of variable degrees. All cases had implantation of a piggyback ICL/toric ICL, to correct the myopia/myopic astigmatism. Preoperatively, we evaluated the uncorrected distance visual acuity (UCVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and endothelial cell density (ECD). We assessed the position and vaulting of the ICLs on slit lamp examination and confirmed by Scheimpflug tomography. Postoperative follow-up was at 1st week and 1, 3, 6, 9, 12, 18 and 24 months.
RESULTS: Uncorrected distance visual acuity improved in all cases, and CDVA improved in 11 amblyopic eyes (2-4 lines). There was no evidence of interlenticular opacification (ILO) throughout the 2-year follow-up. Two cases were complicated with early postoperative acute elevation of IOP and were controlled with topical beta-blockers. Postoperative acute anterior uveitis occurred in six eyes and controlled by topical steroids. Implantable collamer lens (ICL) vault was measured using Pentacam, with mean value of 470 ± 238 μm.
CONCLUSION: Sulcus implantation of the secondary piggyback ICL to correct unilateral pseudophakic myopic refractive error in children was safe, efficient, predictable and well tolerated in management of anisometropic amblyopia in all eyes.
© 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  anisometropic amblyopia; implantable collamer lens; piggyback

Mesh:

Year:  2016        PMID: 27681455     DOI: 10.1111/aos.13203

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  6 in total

Review 1.  The treatment of amblyopia: current practice and emerging trends.

Authors:  Eleni Papageorgiou; Ioannis Asproudis; Gail Maconachie; Evangelia E Tsironi; Irene Gottlob
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-01-31       Impact factor: 3.117

Review 2.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

3.  Refractive outcomes of cataract surgery in primary congenital glaucoma.

Authors:  Sudarshan Khokhar; Dev Yadav; Shikha Gupta; Ramanjit Sihota; Abadh Kishore Chaurasia; Amisha Gupta; Viney Gupta
Journal:  Eye (Lond)       Date:  2018-10-31       Impact factor: 3.775

4.  Pseudophakic ametropia management with toric implantable collamer lens with a central hole (case report).

Authors:  Xun Chen; Xiaoying Wang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2017-02-21       Impact factor: 2.209

5.  Off-Label Use of Phakic Intraocular Lens with a "Piggyback" Technique.

Authors:  Tadgh Schempf; Hoon C Jung
Journal:  Case Rep Ophthalmol       Date:  2018-11-21

6.  A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation.

Authors:  Gernot Iw Duncker; Anna C Sasse; Tobias Duncker
Journal:  Clin Ophthalmol       Date:  2019-09-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.