Literature DB >> 27680571

Influence of Pulse Repetition Frequency on 3-D Power Doppler Quantification.

Carlos A M Soares1, Theo Z Pavan2, Andre H Miyague3, Marek Kudla4, Wellington P Martins5.   

Abstract

Three-dimensional power Doppler quantification has limited application because of its high dependency on attenuation. The purpose of the study described here was to assess if different degrees of attenuation, depending on pulse repetition frequency (PRF) adjustment, alter 3-D power Doppler quantification in a region of 100% moving blood when using vascularization index, flow index and vascularization flow index (VFI). A cubic-shaped gelatin phantom with a 1.8-mm-internal-diameter silicon tube was used. The tube, placed at 45° to the phantom's surface, was filled with blood-mimicking fluid with as constant maximum velocity of 30 cm/s. Two different attenuation blocks (low and high attenuation) were alternatively placed between the phantom and the transvaginal transducer. One single observer acquired 10 data sets for each PRF level from 0.3 to 7.5 kHz, using the high- and low-attenuation blocks, for a total of 200 3-D power Doppler data sets. We assessed VFI from 1.5-mm-diameter spherical samples, virtually placed inside the tube, always at the same position. No difference was noted between high- and low-attenuation VFI values when using a PRF of 0.3 kHz. As PRF increased, it was observed that VFI quantification progressively differed between low and high attenuation. Also, a slope on VFI values for both high- and low-attenuation models could be observed when increasing PRF, particularly above 4.0 kHz. We concluded that PRF adjustment is very relevant when using VFI to quantify 3-D power Doppler signal.
Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Power Doppler; Pulse repetition frequency; Three-dimensional imaging; Vascularization index; Vascularization-Flow Index; flow index

Mesh:

Year:  2016        PMID: 27680571     DOI: 10.1016/j.ultrasmedbio.2016.08.015

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

Review 1.  How to use power Doppler ultrasound in transvaginal assessment of uterine fibroids.

Authors:  M Frijlingh; L Juffermans; R de Leeuw; C de Bruyn; D Timmerman; T van den Bosch; J A F Huirne
Journal:  Ultrasound Obstet Gynecol       Date:  2022-08       Impact factor: 8.678

2.  Transvaginal Real-Time Shear Wave Elastography in the Diagnosis of Endometrial Lesions.

Authors:  Yuan-Yuan Du; Xiao-Jing Yan; Yan-Jing Guo; Jing Wang; Xiao-Duo Wen; Nan Wang; Yi Yang
Journal:  Int J Gen Med       Date:  2021-06-25

3.  4D Doppler Ultrasound in High Grade Serous Ovarian Cancer Vascularity Evaluation-Preliminary Study.

Authors:  Marek Jerzy Kudla; Michal Zikan; Daniela Fischerova; Mateusz Stolecki; Juan Luis Alcazar
Journal:  Diagnostics (Basel)       Date:  2021-03-24
  3 in total