BACKGROUND: As COBE Spectra has been replaced in many parts of the world, we describe a new protocol for low-density lipoprotein (LDL)-apheresis performed on familial hypercholesterolemia patients for the Spectra Optia platform.
METHODS: For all procedures, after administering a bolus of heparin of 2,500 U, 10,000 U of heparin added to a 600 ml ACD-A bag was used as anticoagulant (AC). In a first phase (A), 16 apheresis procedures with COBE Spectra using an inlet:AC ratio of 25:1 were compared to 18 LDL-apheresis treatments with Spectra Optia at split Inlet:AC ratios of 16:1/18:1 or 20:1/25:1. Platelet activation and coagulation markers were assessed. In a follow-up phase (B), 20 procedures on Spectra Optia using an inlet:AC ratio of 20:1 were performed.
RESULTS: Although coagulation markers and platelet activation analyzed were similar in both apheresis devices used, COBE Spectra procedures did not show any visual clumping in the sets. Visual analysis of clumping was highest in the Spectra Optia's 20:1/25:1 AC regimen (5/8 procedures). For the lowest Spectra Optia, AC regimen and during the follow-up phase reversible clump formation in the disposable set was similar (1/10 procedures). Clumping was successfully reversed in all cases by temporarily lowering the inlet:AC ratio to 18:1. Blood cell counts (WBC, Plt, Hct) were similar for both COBE Spectra and Spectra Optia procedures. Spectra Optia had a significantly higher plasma removal efficiency versus COBE Spectra (84% vs.75%, P < .05). No serious adverse events were observed.
CONCLUSION: Apheresis procedures on the Spectra Optia system with low-dose heparin-citrate anticoagulation are feasible and safe.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  LDL-apheresis; Spectra Optia; anticoagulation; citrate; heparin

Mesh:

Substances:

Year:  2016        PMID: 27676234     DOI: 10.1002/jca.21512

Source DB:  PubMed          Journal:  J Clin Apher        ISSN: 0733-2459            Impact factor:   2.821


  1 in total

1.  Factors influencing platelet clumping during peripheral blood hematopoietic stem cell collection.

Authors:  Gagan Mathur; Sarah L Mott; Laura Collins; Gail A Nelson; C Michael Knudson; Annette J Schlueter
Journal:  Transfusion       Date:  2017-02-01       Impact factor: 3.157

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.