Literature DB >> 27671178

An In-VitroEvaluation of Microleakage at the Cervical Margin Between two Different Class II Restorative Techniques Using Dye Penetration Method.

Noor-Ul-Ain Jawaed1, Syed Yawar Ali Abidi1, Fazal-Ur-Rehman Qazi1, Shahbaz Ahmed1.   

Abstract

OBJECTIVE: To evaluate the coronal microleakage of packable composite using conventional incremental and posterior bulk fill flowable composite using Smart Dentine Replacement Single Step technique in the cervical margins of class II cavities in dentine using the dye penetration method. STUDY
DESIGN: In-vitroInterventional study. PLACE AND DURATION OF STUDY: Department of Operative Dentistry, Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences (DIKIOHS), Karachi, from November 2012 to April 2013.
METHODOLOGY: One hundred and twenty extracted teeth (molars and premolars) were collected and randomly divided into two experimental groups (n=60 each) and were stored in normal saline until used. Fractured samples were excluded. Standardized class II proximal box only cavities were prepared and restored with conventional methacrylate based composite using incremental technique (Group A, n=40) and low stress methacrylate resin based composite SDR using single step technique (Group B, n=40). Samples were sectioned horizontally below the cervical margins and specimen disks were prepared. The specimens were thermocycled and sealed with acid resistant varnish leaving a 1-mm interface around cervical margin and immersed in 2% methylene blue buffered solution for 24 hours. Leakage was scored 0 - 4 and measured in mm. It washed and sectioned to evaluate under stereomicroscope.
RESULTS: Mean penetration was 2.4280 ±0.79 mm for Group Aand 1.015 ±0.45 mm for Group B (p < 0.001). Maximum dye penetration score for group Awas 4 and group B was 3.
CONCLUSION: SDR technique in combination with total etch technique at the cervical margin of class II restorations improved the marginal seal, when were placed in dentine and thermocycled.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27671178     DOI: 2428

Source DB:  PubMed          Journal:  J Coll Physicians Surg Pak        ISSN: 1022-386X            Impact factor:   0.711


  2 in total

1.  The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols.

Authors:  Nojoud Alshehri; Abdullah Aljamhan; Mohammed Bin-Shuwaish
Journal:  BMC Oral Health       Date:  2022-05-18       Impact factor: 3.747

2.  Microleakage Evaluation in Class V Cavities Restored with Five Different Resin Composites: In vitro Dye Leakage Study.

Authors:  Sahar Bajabaa; Shaza Balbaid; Muruj Taleb; Lujain Islam; Salem Elharazeen; Ebaa Alagha
Journal:  Clin Cosmet Investig Dent       Date:  2021-09-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.