Literature DB >> 27670068

Canine pulmonary vein-to-pulmonary artery ratio: echocardiographic technique and reference intervals.

F Birettoni1, D Caivano1, V Patata1, N S Moïse2, C Guglielmini3, M Rishniw4, F Porciello5.   

Abstract

OBJECTIVES: The size of the pulmonary veins (PVs) and pulmonary arteries (PAs) changes in response to hemodynamic alterations caused by physiological events and disease. We sought to create standardized echocardiographic methods for imaging the right ostium of the pulmonary veins (RPVs) and the right pulmonary artery (RPA) using specific landmarks and timing to quantify vessel diameters and phasic changes during the cardiac cycle. ANIMALS: Fifty client-owned healthy dogs prospectively recruited.
METHODS: M-mode and 2-dimensional images were obtained from modified right parasternal long and short axis views. Right ostium of the pulmonary veins and RPA measurements were timed with electrical [peak of the QRS complex (RPVQRS and RPAQRS) and end of T wave (RPVT and RPAT)] or mechanical events [RPV and RPA vessels at their respective maximal (RPVMAX; RPAMAX) and minimal (RPVMIN; RPAMIN) diameters]. Right ostium of the pulmonary veins and RPA measurements were also indexed to the aorta.
RESULTS: In normal dogs regardless of the echocardiographic view or time in the cardiac cycle, the RPV/RPA ratio approximated 1.0. Mechanically timed fractional changes (distensibility indices) in RPV and RPA diameters did not differ (p=0.99; 36.9% and 36.8%, respectively). ECG-timed fractional changes (distensibility indices) in RPV and RPA diameter were at least 50% smaller than mechanically timed changes (p<0.05). RPV:Ao and RPA:Ao ranged between 0.3 and 0.6, with lower values obtained in diastole and larger values in systole (p<0.0001). Multiple positive and negative deflections were identified on the RPV and RPA M-mode tracings.
CONCLUSION: This study provides detailed methodology and 2D and M-mode reference intervals for the RPV and RPA dimensions and the phasic changes during the cardiac cycle of the dog using echocardiography.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Healthy dog; Index; Pulmonary artery distensibility index; Pulmonary vein distensibility index

Mesh:

Year:  2016        PMID: 27670068     DOI: 10.1016/j.jvc.2016.07.004

Source DB:  PubMed          Journal:  J Vet Cardiol        ISSN: 1760-2734            Impact factor:   1.701


  3 in total

1.  Transthoracic M-mode echocardiographic assessment of pulmonary vein-to-pulmonary artery ratio in healthy horses.

Authors:  Domenico Caivano; Andrea Corda; Mark Rishniw; Maria Elena Giorgi; Maria Luisa Pinna Parpaglia; Maria Beatrice Conti; Francesco Porciello; Francesco Birettoni
Journal:  PLoS One       Date:  2019-08-14       Impact factor: 3.240

2.  Ultrasonographic assessment of abdominal aortic elasticity in hypertensive dogs.

Authors:  Andrea Corda; Francesca Corda; Domenico Caivano; Laura Saderi; Giovanni Sotgiu; Alessandra Mollica; Francesco Birettoni; Francesco Porciello; Maria Luisa Pinna Parpaglia
Journal:  J Vet Intern Med       Date:  2020-09-19       Impact factor: 3.333

3.  Evaluation of the pulmonary vein ostia during the cardiac cycle using electrocardiography-gated cardiac computed tomography in cats.

Authors:  Junyoung Kim; Dae-Hyun Kim; Kitae Kim; Dayoung Oh; Jihye Choi; Junghee Yoon
Journal:  Front Vet Sci       Date:  2022-09-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.