Literature DB >> 2766682

Single and multiple breath nitrogen wash-out--closing volume and volume of trapped gas for detection of early airway obstruction.

M Dahlqvist1, R Alexandersson, J Nielsen, G Hedenstierna.   

Abstract

Thirty-eight patients with varying degrees of peripheral airway involvement were studied by flow-volume curves and two nitrogen wash-out techniques in an on-site study. Closing capacity (CC), closing volume in percentage of vital capacity (CV%), slope of the alveolar plateau (phase III), volume of trapped gas (VTG), and maximum expiratory flow at 50 and 75% of vital capacity (MEF50, MEF25) were determined and correlation analyses were performed. A biphasic or exponential correlation was noted between the degree of airway closure and VTG with rapidly increasing VTG at high CC. Although there were correlations between spirometry and the two nitrogen wash-out techniques, a large scatter precluded the use of the flow-volume variables to predict CC, CV% and VTG. The coefficient of variation was lower for the measurements of CV% than for the recording of VTG. Since the single breath nitrogen wash-out technique is also technically simpler it is recommended prior to the multiple breath technique.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2766682     DOI: 10.1111/j.1475-097x.1989.tb00992.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  5 in total

1.  What is the "best PEEP" in chronic obstructive pulmonary disease?

Authors:  H Wrigge; C Putensen
Journal:  Intensive Care Med       Date:  2000-09       Impact factor: 17.440

2.  Small airways dysfunction among non-smoking shipyard arc welders.

Authors:  U Hjortsberg; P Orbaek; M Arborelius
Journal:  Br J Ind Med       Date:  1992-06

3.  Small airways function in aluminium and stainless steel welders.

Authors:  J Nielsen; M Dahlqvist; H Welinder; Y Thomassen; R Alexandersson; S Skerfving
Journal:  Int Arch Occup Environ Health       Date:  1993       Impact factor: 3.015

4.  Serum IgE and lung function in workers exposed to phthalic anhydride.

Authors:  J Nielsen; I Bensryd; H Almquist; M Dahlqvist; H Welinder; R Alexandersson; S Skerfving
Journal:  Int Arch Occup Environ Health       Date:  1991       Impact factor: 3.015

5.  Upper airway irritation and small airways hyperreactivity due to exposure to potassium aluminium tetrafluoride flux: an extended case report.

Authors:  U Hjortsberg; P Orbaek; M Arborelius; J E Karlsson
Journal:  Occup Environ Med       Date:  1994-10       Impact factor: 4.402

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.