Literature DB >> 27661866

Agarose coated spherical micro resonator for humidity measurements.

Arun Kumar Mallik, Dejun Liu, Vishnu Kavungal, Qiang Wu, Gerald Farrell, Yuliya Semenova.   

Abstract

A new type of fiber optic relative humidity (RH) sensor based on an agarose coated silica microsphere resonator is proposed and experimentally demonstrated. Whispering gallery modes (WGMs) in the micro resonator are excited by evanescent coupling using a tapered fiber with ~3.3 µm waist diameter. A change in the relative humidity of the surrounding the resonator air induces changes in the refractive index (RI) and thickness of the Agarose coating layer. These changes in turn lead to a spectral shift of the WGM resonances, which can be related to the RH value after a suitable calibration. Studies of the repeatability, long-term stability, measurement accuracy and temperature dependence of the proposed sensor are carried out. The RH sensitivity of the proposed sensor depends on the concentration of the agarose gel which determines the initial thickness of the deposited coating layer. Studies of the micro- resonators with coating layers fabricated from gels with three different Agarose concentrations of 0.5%, 1.125% and 2.25 wt./vol.% showed that an increase in the initial thickness of the coating material results in an increase in sensitivity but also leads to a decrease of quality factor (Q) of the micro resonator. The highest sensitivity achieved in our experiments was 518 pm/%RH in the RH range from 30% to 70%. The proposed sensor offers the advantages of a very compact form factor, low hysteresis, good repeatability, and low cross sensitivity to temperature.

Entities:  

Year:  2016        PMID: 27661866     DOI: 10.1364/OE.24.021216

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  3 in total

Review 1.  Recent Developments in Fiber Optics Humidity Sensors.

Authors:  Joaquin Ascorbe; Jesus M Corres; Francisco J Arregui; Ignacio R Matias
Journal:  Sensors (Basel)       Date:  2017-04-19       Impact factor: 3.576

2.  Relative Humidity Sensor Based on No-Core Fiber Coated by Agarose-Gel Film.

Authors:  Wei Xu; Jia Shi; Xianchao Yang; Degang Xu; Feng Rong; Junfa Zhao; Jianquan Yao
Journal:  Sensors (Basel)       Date:  2017-10-16       Impact factor: 3.576

3.  Silica Gel Coated Spherical Micro resonator for Ultra-High Sensitivity Detection of Ammonia Gas Concentration in Air.

Authors:  Arun Kumar Mallik; Gerald Farrell; Dejun Liu; Vishnu Kavungal; Qiang Wu; Yuliya Semenova
Journal:  Sci Rep       Date:  2018-01-26       Impact factor: 4.379

  3 in total